Connecting up
5.2 Ethernet
SCALANCE MUM856-1
46
Operating Instructions, 08/2021, C79000-G8976-C628-02
Note
The requirements of EN61000-4-5, "Surge Immunity Test" on power supply lines with 24 VDC
are met only when a Blitzductor is used:
24 VDC: BVT AVD 24 type no. 918 422
Vendor: DEHN+SÖHNE GmbH+Co.KG, Hans Dehn Str. 1, Postfach 1640, D - 92306 Neumarkt,
Germany
5.2
Ethernet
For connection to Industrial Ethernet at 10/100/1000 Mbps, the device has an M12 interface:
X-coded, 8-pin.
The power can also be supplied via this interface (Power over Ethernet)
Position and pin assignment
Pin
Assignment
1
D0+
2
D0-
3
D1+
4
D1-
5
D3+
6
D3-
7
D2-
8
D2+
Connecting Ethernet ports
1.
Connect the plug and socket. Make sure that they lock in place correctly.
2.
Tighten the knurled screw (torque 1 Nm).