Connecting up
5.7 Inserting / removing the CLP
SCALANCE MUM856-1
Operating Instructions, 08/2021, C79000-G8976-C628-02
55
Removing the PLUG
Follow the steps below to remove a PLUG from the device:
1.
Turn off the power to the device.
2.
Loosen the screws
③
of the slot cover and remove the slot cover
②
. As an alternative, you
can loosen only one of the screws
③
and swivel the slot cover
②
to the side.
3.
Insert a screwdriver between the front edge of the PLUG (A) and the slot and release the
PLUG
①
.
4.
Remove the PLUG
①
from the slot.
5.
Close the slot cover (torque 0.8 Nm) to ensure that the device is closed, water-proof and
dust-proof.
Note
Loss of the configuration
The reset button is directly beside the slot for the PLUG. The reset button cannot be used to
remove the PLUG.
If you press and hold down the reset button you reset all the settings of the device to the
factory defaults.