Expanding and assigning parameters to the device
6.6 Drives
SIMATIC IPC647E
112
Operating Instructions, 11/2018, A5E45589180-AA
6.6.2.2
Permissible expansion for temperature range 0 °C to 45 °C
Note
If the device is permanently installed or mounted on telescopic rails, or operated as a tower,
it may only be subjected to vibration stress during operation as described below:
The restrictions do not apply for the use of SSD.
The maximum permitted power loss of the expansion cards amounts to 55 W.
You can install the following drives in the Type B drive cage at various mounting locations.
You can find information on the mounting locations under:
●
Drive cage type B (Page 18)
Installation options
The following figure gives you an overview of the installation options for drives.
①
Drive in drive bay for internal
robust installation
②
Drive type "SATA" is possible
③
1 or 2 SSDs permanently in-
stalled
* Only SATA 3.5"
The maximum permitted power loss of the expansion cards amounts to 55 W.
●
10 Hz to 58 Hz:
0,0375
mm
●
58 Hz to 500 Hz: 5 m/s
2
Vibrations may not exceed 500 Hz.
Ambient temperature
0 °C - 45 °C
Drive configuration
Mode
Non-RAID system
X
RAID1 system
X
Содержание SIMATIC IPC647E
Страница 10: ...Table of contents SIMATIC IPC647E 10 Operating Instructions 11 2018 A5E45589180 AA ...
Страница 190: ...Technical support B 2 Troubleshooting SIMATIC IPC647E 190 Operating Instructions 11 2018 A5E45589180 AA ...
Страница 194: ...Markings and symbols C 5 Interfaces SIMATIC IPC647E 194 Operating Instructions 11 2018 A5E45589180 AA ...