Configuration and Parameter Assignment Frame for the IM 178-4
B-6
IM 178-4
C79000-G7076-C178-01
Table B-2 Technological Parameters
Byte Meaning of the bits
What can be assigned
Default
Value
Bit
22
0..3
0
H
With sensor type 1 to 3:
normalization
Number of places by which the
sensor value is shifted right be-
fore it is entered in the user data
area (possible values with an SSI
13-bit position encoder: 0 to 9;
otherwise: 0 to 15)
4..5
00
With sensor type 4 and 5:
synchronization condition
00=software
01=zero mark
10=digital input 1I1
11=digital input 1I1 and zero mark
6..7
00
With actual reference value
generation via 1I0:
edge
selection 1I0
00=none
01=falling edge of 1I0
10=rising edge of 1I0
11=both edges of 1I0
23
00
H
reserved
24
00
H
reserved
Reserve
25
00
H
reserved
26
00
H
reserved
27
00
H
reserved
28
00
H
reserved
29
00
H
reserved
30
00
H
reserved