A-4
OP37/Pro Equipment Manual
Release 7/98
AT expansion box (option)
Slots
2 standard ISA slots
Plug-in AT cards
2/3-length 16-bit cards
Maximum available power for con-
sumption
4
by AT cards at
+5 V
2 A
+12 V
1 A
–5 V
100 mA
–12 V
100 mA
4)
The figures quoted apply to both cards together and must not be exceeded. If only
one AT card is fitted, the maximum levels can be used by that card alone.
Ambient conditions
Ambient temperature
In operation
– vertical installation
– sloping installation not ex-
ceeding 25
°
from vertical
4...40
°
C
4...35
°
C
During shipping, storage
–20...60
°
C
Installation position with FDD
Max. 25
°
inclination to front or rear
Relative air humidity
During operation
20...80%, no moisture condensation
Transport, storage
5...90%, no moisture condensation
Exposure to shock
During operation
5 g / 11 msec for floppy disk/hard disk ac-
cess
15 g / 11 ms at other times
Transport, storage
50 g
Vibration
During operation
0.035 mm (10 – 58 Hz)
1 g (58 – 500 Hz) and
0.5 g with floppy disk drive/hard disk
Transport, storage
3.5 mm (5 – 8.5 Hz)
1 g (8.5 – 500 Hz)
Max. differential pressure (front, rear)
Air pressure
Operation
Shipping, storage
706...1030 hPa
581...1030 hPa
Technical Data
Содержание SIMATIC HMI OP37/Pro
Страница 6: ...iv OP37 Pro Equipment Manual Release 7 98 Preface ...
Страница 8: ...6 10 OP37 Pro Equipment Manual Release 7 98 Servicing Maintenance ...
Страница 26: ...3 8 OP37 Pro Equipment Manual Release 7 98 Electrical Installation ...
Страница 54: ...6 10 OP37 Pro Equipment Manual Release 7 98 Servicing Maintenance ...
Страница 60: ...A 6 OP37 Pro Equipment Manual Release 7 98 Technical Data ...
Страница 72: ...Glossary 2 OP37 Pro Equipment Manual Release 7 98 Glos ...