Commissioning
6.6 Quick commissioning
SIMATIC ET 200pro FC-2 converter
82
Operating Instructions, 04/2018, FW V4.7 SP10, A5E34257324B AF
Summary of settings - Select
Continue
Save Settings
Settings saved
Status Screen displayed
On first ON command - Motor
ID is performed
6.6.2
Quick commissioning with a PC
STARTER and STARTER screen forms
STARTER is a PC-based tool to commission Siemens inverters.
There are two methods of commissioning when using STARTER:
●
You connect the computer, on which STARTER is installed, directly to the inverter via an
appropriate USB cable
●
Using the computer, you access the head module on the inverter via a fieldbus cable. In
this case, the control must be switched off.
Components for assembling a frequency converter (Page 25)
The graphic user interface of STARTER supports you when commissioning. Most inverter
functions are combined in screen forms in STARTER.
Commissioning the inverter when it is directly connected to the computer via a USB cable is
described in the following.