Detailed descriptions
16.1 Motherboard
SIMATIC Box PC 627
Operating Instructions, Release 05/2006, A5E00362052-03
16-5
PROFIBUS / MPI interface, X600
PROFIBUS/MPI interface
1)
PinNo.
Abbreviation
Meaning
Input /Output
1
–
Not assigned
–
2
–
Unassigned
–
3
LTG_B
Signal line B of MPI module
Input/output
4
RTS_AS
RTSAS, control signal for received data
stream. The signal is "1" active when the
directly connected PLC is sending.
Input
5
M5EXT
M5EXT return line (GND) of the 5 V power
supply. The current load caused by an external
consumer connected between P5EXT and
M5EXT must not exceed the maximum of
90 mA.
Output
6
P5 EXT
P5EXT power supply (+5 V) of the 5 V power
supply. The current load caused by an external
consumer connected between P5EXT and
M5EXT must not exceed the maximum of
90 mA.
Output
7
–
not assigned
–
8
LTG_A
Signal line A of MPI module
Input/output
9
RTS_PG
RTS output signal of the MPI module. The
control signal is "1" when the PG is sending.
Output
Shield
on connector casing
1
Optional product feature
Содержание SIMATIC Box PC 627
Страница 2: ......
Страница 24: ...Description 3 7 Design SIMATIC Box PC 627 3 12 Operating Instructions Release 05 2006 A5E00362052 03 ...
Страница 52: ...Integration SIMATIC Box PC 627 8 2 Operating Instructions Release 05 2006 A5E00362052 03 ...
Страница 168: ...Detailed descriptions 16 4 BIOS Setup SIMATIC Box PC 627 16 50 Operating Instructions Release 05 2006 A5E00362052 03 ...
Страница 174: ...Appendix A 3 Service and support SIMATIC Box PC 627 A 6 Operating Instructions Release 05 2006 A5E00362052 03 ...
Страница 182: ...Abbreviations C 1 Abbreviations SIMATIC Box PC 627 C 6 Operating Instructions Release 05 2006 A5E00362052 03 ...
Страница 192: ...Glossary SIMATIC Box PC 627 Glossary 10 Operating Instructions Release 05 2006 A5E00362052 03 ...
Страница 198: ...Index SIMATIC Box PC 627 Index 6 Operating Instructions Release 05 2006 A5E00362052 03 ...
Страница 199: ......