Terminal cover offset
The terminal cover offset always consists of two parts:
①
Rear insulating plate, provides insulation from the panel mounting plate
②
Front half, pushed over the molded case circuit breaker from the front
The insulating plate is fitted to the rear panel of the molded case circuit breaker and then
secured by 2 screws to the front half of the terminal cover. The terminal cover offset is also
secured by 2 additional screws to the molded case circuit breaker itself.
The terminal cover offset is compatible with:
●
Front bus connectors offset
Insulating plate and insulating plate offset
If insulation for the mounting plate is needed, this can be ensured by an insulating plate.
The insulating plate is fitted to the rear panel of the molded case circuit breaker and can be
installed in combination with phase barriers.
Potential applications:
●
Insulating plate:
–
Bus connectors, extended
–
Non-insulated, straight conductors / terminals
●
Insulating plate, offset:
–
Bus connectors, offset