Technical data
8.2 Technical specifications of the SCALANCE XR528-6M
SCALANCE XR-500
Operating Instructions, 05/2014, A5E03275845-05
79
Technical specifications
Permitted ambient conditions
Operating temperature
Operation without filter pad and
without SFP+ LH transceiver
0 to +60 °C
Operation with filter pad and
without SFP+ LH transceiver
0 to +55 °C
Operation with filter pad and
with SFP+ LH transceiver
0 to +50 °C
Ambient temperature
During operation up to 2000 m
-
40 ℃ to +65 ℃
During operation up to 3000 m
-
40 ℃ to +50 ℃
During storage
-
40 ℃ to +70 ℃
During transportation
-
40 ℃ to +70 ℃
Relative humidity
During operation at 25 ℃
≤ 95%, no condensation
Design, dimensions and weight
Weight (basic device without media
modules)
7.2 kg
Degree of protection (with closed
service panel)
IP20
Dimensions without brackets for
19" rack mounting (W x H x D)
446 x 88 x 305 mm (2 height units)
Installation options
•
19" rack mounting
•
Desktop operation
•
Four-point mounting
Design of the mounting bracket for use on ships
Dimensions without brackets for
19" rack mounting (W x H x D)
60 x 87.1 x 18.3 mm (2 height units)
Plate thickness
1.5 mm
Bending radii
1.5 mm
Surface of the housing
Stainless steel X6CR17
Mean time between failure (MTBF)
•
Basic device without media
modules
•
at 40 °C ambient temperature
> 17.1 years
Note
ISO tolerance and punching burr
For dimensions without tolerance details, the general tolerances "medium" acc. to DIN ISO
2768 apply. No punching burrs are permitted.