Description of the device 

 

3.3 LED display 

 

SCALANCE XR-500 

18

 

Operating Instructions, 05/2014, A5E03275845-05 

3.3

 

LED display 

3.3.1

 

The "RM" LED for the "redundancy manager" function 

The "RM" LED indicates whether or not the device is a redundancy manager and whether or 

not the ring is operating free of error. 

 

LED color 

LED status 

Meaning 

Off 

The device is not a redundancy manager. 

Green 

On  

The device is a redundancy manager. 
The ring is working without problems, monitoring is activated. 

Green 

Flashing 

The device is a redundancy manager. 
An interruption has been detected on the ring and the device 

has switched through. 

3.3.2

 

The "SB" LED for the standby function 

The "SB" LED shows the status of the standby function. 

 

LED color 

LED status 

Meaning 

Off 

The standby function is disabled. 

Green 

On 

The standby function is enabled. The standby section is 

passive.  

Green 

Flashing 

The standby function is enabled. The standby section is active. 

Содержание SCALANCE XR524-8C

Страница 1: ..._______ ___________________ ___________________ ___________________ SIMATIC NET Industrial Ethernet switches SCALANCE XR 500 Operating Instructions 05 2014 A5E03275845 05 Introduction 1 Safety notes 2 Description of the device 3 Assembling 4 Connecting 5 Uninstalling 6 Upkeep and maintenance 7 Technical data 8 Dimension drawings 9 Certification 10 ...

Страница 2: ... only by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens p...

Страница 3: ...e C PLUG KEY PLUG 25 3 5 Combo ports 27 4 Assembling 29 4 1 Safety notices for installation 29 4 2 Types of installation 31 4 3 19 rack mounting 31 4 4 Desktop operation with adhesive feet 33 4 5 Four point mounting 34 4 6 Plugging and pulling MM900 media modules 36 4 7 Inserting and removing media pluggable transceivers 40 4 7 1 Notes on inserting removing pluggable transceivers 40 4 7 2 Insertin...

Страница 4: ...intenance 67 7 1 Changing the fan unit 67 7 2 Changing the filter pad 70 7 3 Downloading new firmware using TFTP without WBM and CLI 72 7 4 Restoring the factory settings 73 8 Technical data 75 8 1 Technical specifications of the SCALANCE XR524 8C 75 8 2 Technical specifications of the SCALANCE XR528 6M 78 8 3 Technical specifications of the SCALANCE XR552 12M 80 8 4 Switching properties 82 9 Dime...

Страница 5: ...CALANCE XR552 12M Designations used Classification Description Terms used Product line If information applies to all product groups within the product line the term SCALANCE XR 500 is used SCALANCE XR 500 Device If information relates to a specific device the device name is used SCALANCE XR524 8C SCALANCE XR528 6M SCALANCE XR552 12M Variant For a variant of the device the device name has the appro...

Страница 6: ...On the data medium that ships with some products Product CD product DVD SIMATIC NET Manual Collection On the Internet pages of Siemens Industry Online Support under the following entry IDs 27069465 http support automation siemens com WW view en 27069465 Industrial Ethernet PROFINET Industrial Ethernet System Manual 84922825 http support automation siemens com WW view en 84922825 Industrial Etherne...

Страница 7: ... catalog and ordering system for automation and drive technology Online catalog You can request the catalogs and additional information from your Siemens representative Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants solutions machines equipment and or networks They are important components in a holistic in...

Страница 8: ... parts there is no guarantee that the device will function according to the specification If you use damaged parts this can lead to the following problems Injury to persons Loss of the approvals Violation of the EMC regulations Damage to the device and other components Use only undamaged parts 1 Make sure that the package is complete 2 Check all the parts for transport damage ...

Страница 9: ... in nuclear power plants or other nuclear facilities WARNING Maximum ambient temperature The operating temperature of a device of the SCALANCE XR 500 product line depends on the ambient temperature For SCALANCE XR524 8C the ambient temperature must not exceed 70 C For SCALANCE XR528 6M and SCALANCE XR552 12M the ambient temperature must not exceed 60 C WARNING Suitable installation location The in...

Страница 10: ... characteristics B or C for circuit breakers and fuses Suitable for the protection of DC power supply circuits Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING Opening the device Do not open when energized Note that this does not apply to opening the service panel in the housing Safety notices when using the device according to Hazard...

Страница 11: ... 240 VAC connector for the power supply on the rear layer 3 without KEY PLUG 6GK5 524 8GS00 4AR2 1 height unit 8 combo ports 2 x 100 to 240 VAC connector for the power supply on the rear 6GK5 524 8GR00 4AR2 1 height unit 8 combo ports 2 x 100 to 240 VAC connector for the power supply on the rear layer 3 without KEY PLUG XR528 6M 6GK5 528 0AA00 2AR2 2 height units 6 modules 6GK5 528 0AA00 2HR2 2 he...

Страница 12: ...tion M3 x 5 countersunk Drive Torx M3 x 6 countersunk Drive Torx M3 x 6 countersunk Drive Torx 4 adhesive feet for desktop operation 2 mounting plates and 24 screws for mounting the power supply units M3 x 6 countersunk drive Torx 4 pin terminal block for the 24 VDC power supply With variants with 24 VDC 2 pin terminal block for the signaling contact Connecting cable for the serial interface with ...

Страница 13: ...00 0XA0 Power cable 100 to 240 VAC straight 3 m For Italy 6ES7 900 0EA00 0XA0 Power cable 100 to 240 VAC straight 3 m For China 6ES7 900 0FA00 0XA0 SFP transceiver Type Order number SFP991 1 6GK5 991 1AD00 8AA0 SFP991 LD 6GK5 991 1AF00 8AA0 SFP991 LH 6GK5 991 1AE00 8AA0 SFP991 1ELH200 6GK5 991 1AE30 8AA0 SFP992 1 6GK5 992 1AL00 8AA0 SFP992 1LD 6GK5 992 1AM00 8AA0 SFP992 1LH 6GK5 992 1AN00 8AA0 SFP...

Страница 14: ... SCALANCE XR528 6M and SCALANCE XR552 12M The following additional accessories are available for devices SCALANCE XR528 6M and SCALANCE XR552 12M Media modules Type Order number MM991 4 6GK5 991 4AB00 8AA0 MM991 4LD 6GK5 991 4AC00 8AA0 MM992 4 6GK5 992 4AL00 8AA0 MM992 4LD 6GK5 992 4AM00 8AA0 MM992 4CU 6GK5 992 4SA00 8AA0 MM992 4CUC 6GK5 992 4GA00 8AA0 MM992 4PoE 6GK5 992 4QA00 8AA0 MM992 4PoEC 6G...

Страница 15: ...E XR552 12M only with a correctly fitted fan unit Operation without the fan is not possible and would damage the device Type Order number FAN597 1 for SCALANCE XR552 12M 6GK5 597 1AA00 8AA0 FAN597 2 for SCALANCE XR528 6M 6GK5 597 2AA00 8AA0 Power supply units The power supply units allow operation with input voltages of 100 to 240 VAC Type Order number PS598 1 100 to 240 VAC 300 W 6GK5 598 1AA00 3...

Страница 16: ...e 19 and Port P1 P2 LEDs for the port status Page 22 Resetting the device to factory defaults If you reset all the changes you have made will be overwritten by factory defaults To reset the device to the factory defaults follow the steps below 1 Switch to display mode A Display mode A is active when the LEDs DM1 and DM2 are off When the LEDs DM1 and DM2 are lit or flashing you need to press the SE...

Страница 17: ...ds After 2 seconds the DM1 and DM2 LEDs start to flash for 3 seconds At the same time the port LEDs go on one after the other After you have pressed the button for 5 seconds the current settings are stored as the good status If you release the button before the 5 seconds are up the previous fault mask is retained Enabling disabling the redundancy manager To enable disable the redundancy manager fo...

Страница 18: ...ndancy manager Green On The device is a redundancy manager The ring is working without problems monitoring is activated Green Flashing The device is a redundancy manager An interruption has been detected on the ring and the device has switched through 3 3 2 The SB LED for the standby function The SB LED shows the status of the standby function LED color LED status Meaning Off The standby function ...

Страница 19: ...e Meaning during operation LED color LED status Meaning during operation Off The device is operating free of errors Red On The device has detected a problem The signaling contact has opened 3 3 4 DM1 and DM2 LEDs for the display mode The DM1 and DM2 LEDs indicate which display mode is set There are 5 display modes A B C D and E Display mode A is the default mode Depending on the set display mode t...

Страница 20: ...he current range of the power supply at connectors L1 and L2 The meaning of the L1 and L2 LEDs depends on the set display mode see section DM1 and DM2 LEDs for the display mode Page 19 Voltage limit For devices with 24 VDC the voltage limit is 17 VDC With devices with 100 to 240 VAC the voltage limit is 90 VAC Meaning in display modes A B C and E In display modes A B C and D from the L1 and L2 LED...

Страница 21: ...upply is not monitored If the power supply falls below 17 VDC the signaling contact does not respond Green On Power supply is monitored If the power supply falls below 17 VDC the signaling contact responds Table 3 4 Monitoring for devices with 100 to 240 VAC L1 L2 LED L1 L2 connector LED color LED status Off Power supply is not monitored If the power supply falls below 90 VAC the signaling contact...

Страница 22: ...ed off by management In this status no data is sent or received via the port Flashes four times per period Link exists and port is in the monitor port status In this status the data traffic of another port is mirrored to this port Yellow Flashing lit Receiving data at port 1 period 2 5 seconds Note LEDS for the SFP slots of the SCALANCE XR 500 If SFP slots of the SCALANCE XR 500 have SFP transceiv...

Страница 23: ...is monitored LED color LED status Meaning Off Port is not monitored Green On Port is monitored for Link down If no link was established at the port e g cable not plugged in the signaling contact indicates an error Yellow On Port is monitored for Link up If a link was established at the port the signaling contact indicates an error Meaning in display mode E In display mode E the port LEDs indicate ...

Страница 24: ... a device In addition to the configuration a KEY PLUG also contains a license with which layer 3 functionality is enabled Note The device can also be operated without a C PLUG KEY PLUG How it works Operating mode In terms of the C PLUG KEY PLUG there are three modes for the device Without C PLUG KEY PLUG The device stores the configuration in internal memory This mode is active if no C PLUG KEY PL...

Страница 25: ...UG are signaled by the diagnostics mechanisms of the device LEDs Web based management WBM SNMP Command Line Interface CLI and PROFINET diagnostics The user then has the choice of either removing the C PLUG KEY PLUG again or selecting the option to reformat the C PLUG KEY PLUG 3 4 2 Removal and insertion of the C PLUG KEY PLUG NOTICE Do not remove or insert a C PLUG KEY PLUG during operation A C PL...

Страница 26: ...EY PLUG position A and the slot and release the C PLUG KEY PLUG 4 Remove the C PLUG KEY PLUG and screw the cover plate firmly in place again Inserting a C PLUG KEY PLUG 1 Turn off the power to the device 2 Remove the cover 3 The housing of the C PLUG KEY PLUG has a protruding ridge on the long side position B The slot has a groove at this position Insert the C PLUG KEY PLUG into the slot correctly...

Страница 27: ...e LEDs for the combo ports can be identified by a vertical line and the word COMBO The labeling of the combo port LEDs does not differ from that of the other LEDs e g P3 Setting the mode The following modes can be configured for a combo port Mode 1 auto The SFP transceiver port has priority As soon as an SFP transceiver is plugged in an existing connection at the fixed RJ 45 port is terminated If ...

Страница 28: ...Description of the device 3 5 Combo ports SCALANCE XR 500 28 Operating Instructions 05 2014 A5E03275845 05 ...

Страница 29: ...ed the temperature inside the housing can rise and exceed the maximum permitted temperature causing damage to the device The ventilation slits are located on the side panels of the housing During installation select a mounting position so that the ventilation slits are always free so that the air can circulate The clearance to the ventilation slits of the housing must be at least 10 cm You will fi...

Страница 30: ...ral safety notices relating to protection against explosion WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I DIVISION 2 OR ZONE 2 WARNING When used in hazardous environments corresponding to Class I Division 2 or Class I Zone 2 the device must be installed in a cabinet or a suitable enclosure Safety notices for use according to ATEX and IECEx If you use the de...

Страница 31: ...ng SFP transceivers in media modules for SFP or SFP slots Inserting removing SFP transceivers in SFP slots Mounting power supply units 4 3 19 rack mounting Notes on 19 rack mounting Note Mounting with two mounting brackets The device is installed using two mounting brackets on the front of the rack device After fitting the two mounting brackets the rack device can then be installed in a 19 cabinet...

Страница 32: ... the same way To mount the device in a 19 rack follow the steps below 1 Secure the two mounting brackets with four screws each M3 x 6 supplied with the product to the side panels of the device The maximum tightening torque for these screws is 0 5 Nm The dimensions of the mounting brackets depend on the height units of the device 2 Position the device at the required location and screw the device t...

Страница 33: ...ation is possible without restrictions Desktop operation of the SCALANCE XR528 6M and SCALANCE XR552 12M devices is permitted only when the power supply units are fitted to them With SCALANCE XR524 8C desktop operation is possible without restrictions Note Strain relief for the cables A cable duct or cable tray must be present at a suitable distance from the device to provide strain relief Procedu...

Страница 34: ...evice is mounted Bracket To install a SCALANCE XR 500 on a ship horizontally you require special mounting brackets You will find the design drawings for constructing the mounting brackets in the section Mounting brackets for use on ships Page 86 Mounting brackets for a SCALANCE XR524 8C For the SCALANCE XR524 8C the mounting brackets for left and right are identical For the SCALANCE XR524 8C you c...

Страница 35: ...l the device with a four point mounting follow the steps below 1 Secure the four mounting brackets each with four countersunk screws M3 x 6 supplied with the product to the side panels of the device The maximum tightening torque for these screws is 0 5 Nm The dimensions of the mounting brackets depend on the height units of the device 2 Position the device at the required location and screw the de...

Страница 36: ...les MM900 of the SCALANCE XR 500 IE switches product line Note Slots for PoE modules You can only use PoE modules in slots 1 2 and 3 refer to the following section Identification of the media module slots and ports Note Factory defaults of the media modules When inserting a media module the parameters of the ports are set to the factory defaults First plug a media module into the device and then a...

Страница 37: ... P4 P1 P2 P3 P4 Slot 4 5 6 Port P1 P2 P3 P4 P1 P2 P3 P4 P1 P2 P3 P4 Slot 0 Port SFP P1 P2 P3 P4 Slot 7 8 9 Port P1 P2 P3 P4 P1 P2 P3 P4 P1 P2 P3 P4 Slot 10 11 12 Port P1 P2 P3 P4 P1 P2 P3 P4 P1 P2 P3 P4 A SCALANCE XR528 6M has a total of six slots and four SFP ports Note Slot number In modular devices the MM900 media modules can be assigned a slot number The labels for the slot numbers ship with t...

Страница 38: ... the steps below 1 Remove the dummy cover of the device slot into which you want to insert a media module 2 Pull the handle out of the media module The media module cannot be installed unless the handle is pulled out 3 Place the media module in the guide rails of the device slot The media module is correctly installed when it locks easily into the device and the front panel of the module is flush ...

Страница 39: ...dia modules inserted or are closed by dummy covers Do not start up the device with open module slots since the ingress of objects can lead to damage If you operate the device with open module compartments it is also not possible to guarantee the maximum ambient temperature Exchanging media modules with change of medium Exchanging a media module If you replace an electrical media module with an opt...

Страница 40: ...s The modular devices have four fixed slots for SFP transceivers It is however possible to operate SFP transceivers in the fixed SFP slots of the device Note that the SFP slots only support SFP transceivers with a transmission rate of 1000 Mbps Note The media module MM992 4SFP and the SFP slots may only be fitted with approved SFP or SFP transceivers The SFP media module can be fitted with up to f...

Страница 41: ...il you hear it engage The connecting cable is then firmly secured 4 7 3 Removing an SFP SFP transceiver Notes on deinstallation CAUTION Risk of burns due to the high temperatures of the pluggable transceiver The SFP SFP transceivers can be plugged and pulled during operation Leave the transceiver to cool down as much as possible Procedure Follow the steps below to remove an SFP SFP transceiver 1 R...

Страница 42: ...ilation slits are on the sides of both the basic device and the power supply unit CAUTION Risk of injury if subjected to irregular mechanical strain The device must be mounted in the rack so that even if there is irregular mechanical strain no dangerous situation can result Procedure Figure 4 4 19 rack mounting of the power supply unit To mount the PS598 1 power supply unit in a 19 rack follow the...

Страница 43: ...S598 1 power supply unit on the rear panel of the following devices SCALANCE XR528 6M SCALANCE XR552 12M Procedure Figure 4 5 Rear panel mounting of the SCALANCE XR552 12M SCALANCE XR528 6M is used analogously On the rear panel of an IE switch there are sockets for the direct connection of a maximum of two PS598 1 power supply units On the rear of the PS598 1 power supply unit there is a correspon...

Страница 44: ...n IE switch follow the steps below 1 Fit the PS598 1 power supply unit and the IE switch together The two devices are equipped with positioning elements that must engage during installation and protect the plug from excessive bending strain 2 Screw the two devices to the mounting plates supplied with the main device The maximum tightening torque of the screws is 0 5 Nm ...

Страница 45: ...les to incorrectly configured ports causes overload in the network and a breakdown in communication A device may only be inserted in a network and connected in the following situations With HRP MRP Ring redundancy must be activated The mode must be selected correctly The ring ports of the device being inserted in the HRP MRP ring must be configured as ring ports With standby link The standby conne...

Страница 46: ...s according to NEC or CEC Suitable for DC min 60 V 25 A Breaking current at least 10 kA Approval according to ANSI UL 248 1 Suitable for the protection of DC power supply circuits In other areas Suitable for DC min 60 V 25 A Breaking current at least 10 kA Approval in compliance with IEC 60127 1 EN 601127 1 Breaking characteristics B or C for circuit breakers and fuses Suitable for the protection ...

Страница 47: ...ep to the following safety notices in addition to the general safety notices for protection against explosion WARNING Take measures to prevent transient voltage surges of more than 40 of the rated voltage This is the case if you only operate devices with SELV safety extra low voltage Safety notices when using the device according to Hazardous Locations HazLoc If you use the device under HazLoc con...

Страница 48: ...umarkt Germany Information on the power supply The power supply is connected using a 4 pin plug in terminal block The terminal block ships with the device The power supply can be connected redundantly Both inputs are isolated There is no distribution of load When a redundant power supply is used the power supply unit with the higher output voltage supplies the SCALANCE XR 500 alone The power suppl...

Страница 49: ...via the modular devices The SFP transceivers are supplied with suitable voltage via the SFP media module in a modular device Position and assignment Figure 5 1 Position of the terminal block on a SCALANCE XR524 8C Figure 5 2 Position of the terminal block on a SCALANCE XR552 12M SCALANCE XR528 6M is analogous Contact Assignment L1 24 VDC M1 Ground M2 Ground L2 24 VDC ...

Страница 50: ...00 to 240 VAC voltage supply do not have an ATEX approval Devices with a 100 to 240 VAC voltage supply are not approved for use in hazardous areas according to EC RL 94 9 ATEX NOTICE Securing cables with dangerous voltage Make sure that the connector cannot be released accidentally by pulling on the connecting cable Lay the cables in cable ducts or cable channels and secure the cables where necess...

Страница 51: ...ear of the SCALANCE XR524 8C The second IEC plug for the redundant version is shown in gray in the figure Switch S1 Power Socket X1 Figure 5 3 Position of the IEC connector on a SCALANCE XR524 8C Grounding WARNING Danger from line voltage Grounding simply via the housing is inadequate In this case connect the functional ground to ensure reliable operation The grounding bolt is located on the rear ...

Страница 52: ...0 VAC NOTICE Connect and disconnect the power supply unit only when it is not energized The PS598 1 power supply unit is not capable of hot plugging Connecting or disconnecting the PS598 1 when the 100 to 240 VAC power supply is on can damage the PS598 1 power supply unit and the IE switch Before connecting or disconnecting the PS598 1 power supply unit make sure that the switch for the input volt...

Страница 53: ...anteed This applies in particular to power supply cables that are not connected directly to the power supply circuit With the PS598 1 power supply unit the IEC power connector IEC 60320 1 provides the connection to protective earth Pin assignment of the X2 socket on the front Figure 5 5 Position of the socket X2 on the PS598 1 power supply unit Contact Assignment L 24 VDC M Ground M Ground L 24 VD...

Страница 54: ...he plug X3 on the PS598 1 power supply unit Contact Assignment L 24 VDC L L M Ground M M One PS598 1 per device no redundancy Figure 5 7 Connecting a power supply unit to a SCALANCE XR552 12M SCALANCE XR528 6M is used analogously Connect the IE switch and the PS598 1 with one cable for 24 VDC and a cable for ground As an alternative you can also mount the PS598 1 on the rear of the IE switch and s...

Страница 55: ...o PS598 1 power supply units on the rear of the IE switch and secure them with screws In this case no extra cables are necessary You will find detailed information in the section Assembling Page 29 It is also possible to operate the IE switch even after the failure of one PS598 1 The IE switch detects the failure of a power source and signals the failure The PS598 1 units share the applied load au...

Страница 56: ...two connectors with the output voltage 24 VDC Note that you can only use the connector on the front or the connector on the rear of the PS598 1 You cannot operate the device with the connectors on the front and rear at the same time Note To wire up the power supply connector use copper cable of the category 14 AWG to 10 AWG or cable with a cross sectional area of 1 5 to 4 mm2 5 3 2 2 LED display o...

Страница 57: ...tact The signaling contact is connected to a 2 pin plug in terminal block NOTICE Damage due to voltage being too high The maximum load on the signaling contact is 24 VDC and 100 mA safety extra low voltage SELV Higher voltages or currents can damage the device Position and assignment Figure 5 10 Position of the signaling contact on a SCALANCE XR524 8C Figure 5 11 Position of the signaling contact ...

Страница 58: ...lt LED F freely configurable are also signaled by the signaling contact If an internal fault occurs the fault LED F lights up and the signaling contact opens If you connect a communications node to an unmonitored port or disconnect it this does not cause an error message The signaling contact remains open until one of the following events occurs The problem is eliminated The current status is ente...

Страница 59: ...200 8N1 connection without assigning an IP address Access to the device is also possible independent of the Ethernet ports To connect the serial interface to the PC you require a cable with an RJ 11 plug and 9 pin D sub female connector The connecting cable for the serial interface ships with the device Position Figure 5 12 Position of the RJ 11 jack on a SCALANCE XR524 8C Figure 5 13 Position of ...

Страница 60: ...lowing assignment Contact Pin assignment of the RJ 11 plug Pin assignment of the D sub female connector 1 2 TD Transmit Data 3 TD Transmit Data RD Receive Data 4 SG Signal Ground 5 RD Receive Data SG Signal Ground 6 7 8 9 Note Pin assignment of the RJ 11 jack on the device The RJ 11 jack on the device has a pinout to match the RJ 11 plug of the supplied connecting cable ...

Страница 61: ... on the CPU module The out of band interface is not used for routing or switching Access to the device is also possible independent of the other Ethernet ports The out of band interface allows direct IP access to the WBM of the device Position Figure 5 14 Position of the out of band interface on a SCALANCE XR524 8C Figure 5 15 Position of the out of band interface on a SCALANCE XR552 12M SCALANCE ...

Страница 62: ...ks A and B is shown in the graphic below Figure 5 16 Block architecture of the SCALANCE XR552 12M Communication between the switch blocks is via two connections each operating at 13 6 Gbps This bandwidth must be shared by all ports for inter block data transfer For this reason ports between which a lot of data is transferred should ideally belong to the same switch block Note that the SCALANCE XR5...

Страница 63: ...r the grounding cable is in the center of the rear panel of the device With a SCALANCE XR552 12M and SCALANCE XR528 6M grounding is achieved with a screw in bolt The SCALANCE XR524 8C has a pressed in grounding bolt Fitting grounding bolts Toothed washer Grounding bolt To fit the grounding bolt for a SCALANCE XR552 12M and SCALANCE XR528 6M follow the steps below 1 Thread the toothed washer onto t...

Страница 64: ...ional ground SCALANCE XR552 12M and SCALANCE XR528 6M SCALANCE XR524 8C Grounding terminal with cable Washer Spring washer Nut Follow the steps below to connect the functional ground 1 Put the parts and together on the grounding bolt as shown in the drawing 2 Tighten the nut with a maximum tightening torque of 1 5 Nm ...

Страница 65: ...vice 1 Remove all connectors 2 Remove the power supply unit units from the rear of the device 3 When necessary release the locking mechanisms on the rack device such as the handles on the media modules or the clip on the SFP SFP to be able to remove the media modules MM900 or the transceivers SFP SFP ...

Страница 66: ...Uninstalling SCALANCE XR 500 66 Operating Instructions 05 2014 A5E03275845 05 ...

Страница 67: ...le and would damage the device You can however replace the fan unit during operation Note the following parameter requirements Requirement If you replace the fan unit during operation the ventilation of the housing may be interrupted at an ambient temperature of 60 C 50 C for a maximum of 30 seconds an ambient temperature of 40 C 50 C for a maximum of 1 minute an ambient temperature lower than 40 ...

Страница 68: ...r Figure 7 1 Opening the housing of a SCALANCE XR552 12M SCALANCE XR528 6M is used analogously 2 Open the door in the housing WARNING Danger of injury by touching rotating fan blades There is a risk of injury if you touch rotating fan blades Do not touch rotating fan blades Allow the fan blades to come to a stop 3 Pull the fan unit out of the housing using the handle on the fan unit Note that the ...

Страница 69: ...E XR552 12M SCALANCE XR528 6M is used analogously 5 Push the new fan unit into the slot along the guide rails 6 Push the filter frame into the slot along the guide rails 7 Close the cover and lock it by pushing the catch from right to left with a slotted screwdriver Note After turning on the basic device the fans rotate at full speed for approximately 1 minute before the fan controller becomes act...

Страница 70: ...lation A badly contaminated filter reduces air flow and can cause the device to be damaged Check the degree of contamination of the filter regularly and clean or replace the filter mat as necessary Procedure Follow the steps below to replace the filter pad 1 Unlock the door in the housing by pushing the catch to the right with a slotted screwdriver Figure 7 3 Opening the housing of a SCALANCE XR55...

Страница 71: ...of the filter frame Figure 7 4 Changing the filter pad of a SCALANCE XR552 12M SCALANCE XR528 6M is used analogously 4 Remove the filter pad 5 Clean or replace the filter pad 6 Insert the cleaned or new filter mat in the filter frame 7 Insert the filter frame in the compartment again 8 Close the cover and lock it by pushing the catch from right to left with a slotted screwdriver ...

Страница 72: ...er to the device while holding down the button 3 Hold down the button until the red fault LED F starts to flash after approximately 30 seconds 4 Now release the button The bootloader of the device waits in this status for a new firmware file that you can download by TFTP 5 Connect a PC to the out band interface of the device via an Ethernet cable 6 Assign an IP address to the device using DHCP or ...

Страница 73: ...u to reset the device to the factory defaults in an emergency If the function has been disabled with the WBM or CLI it is only disabled on completion of the startup phase CAUTION Inadvertent reset An inadvertent reset can cause disturbances and failures in the configured network To reset the device parameters to the factory defaults follow the steps below 1 Turn off the power to the device 2 Now p...

Страница 74: ...Upkeep and maintenance 7 4 Restoring the factory settings SCALANCE XR 500 74 Operating Instructions 05 2014 A5E03275845 05 ...

Страница 75: ...Connector SFP transceiver Transmission speed 100 1000 Mbps Diagnostics interface Serial interface Quantity 1 Connector RJ 11 jack Out of band interface Quantity 1 Connector RJ 45 jack Signaling contact Quantity 1 Design Terminal block 2 terminals Permitted voltage range 24 VDC Load capability max 100 mA Connection to power supply 2 x 24 VDC Design Terminal block 4 terminals Rated voltage 24 VDC Vo...

Страница 76: ... pin Rated voltage 100 240 VAC Voltage range 90 to 264 VAC Frequency 60 Hz 50 Hz Frequency range 47 Hz to 63 Hz Fusing 3 15 A 250 V Current consumption at 100 VAC 0 22 A Current consumption at 240 VAC 0 17 A Effective power loss 24 W Properties Implemented redundantly Permitted ambient conditions Ambient temperature For devices with a 24 VDC During operation up to 2000 m 40 to 70 During operation ...

Страница 77: ...x 24 VDC 21 1 years 1 x 100 to 240 VAC 10 9 years 2 x 100 to 240 VAC 14 4 years When working with electrical connectors make sure that the isolation between the ports is maintained see Isolation between ports Note ISO tolerance and punching burr For dimensions without tolerance details the general tolerances medium acc to DIN ISO 2768 apply No punching burrs are permitted Isolation between ports S...

Страница 78: ... 1 Design Terminal block 2 terminals Permitted voltage range 24 VDC Load capability max 100 mA Connection to power supply 24 VDC power supply Design Terminal block 4 terminals Rated voltage 24 VDC Voltage range 19 2 VDC 28 8 VDC Fusing 3 15 A 125 V Cable cross section Minimum Maximum 0 75 mm2 18 AWG 2 5 mm2 12 AWG Properties Implemented redundantly Connector for power supply unit PS598 1 Quantity ...

Страница 79: ...condensation Design dimensions and weight Weight basic device without media modules 7 2 kg Degree of protection with closed service panel IP20 Dimensions without brackets for 19 rack mounting W x H x D 446 x 88 x 305 mm 2 height units Installation options 19 rack mounting Desktop operation Four point mounting Design of the mounting bracket for use on ships Dimensions without brackets for 19 rack m...

Страница 80: ... 1 Design Terminal block 2 terminals Permitted voltage range 24 VDC Load capability max 100 mA Connection to power supply 24 VDC power supply Design Terminal block 4 terminals Rated voltage 24 VDC Voltage range 19 2 VDC 28 8 VDC Fusing 3 15 A 125 V Cable cross section Minimum Maximum 0 75 mm2 18 AWG 2 5 mm2 12 AWG Properties Implemented redundantly Connector for power supply unit PS598 1 Quantity ...

Страница 81: ...densation Design dimensions and weight Weight basic device without media modules 10 kg Degree of protection with closed service panel IP20 Dimensions without brackets for 19 rack mounting W x H x D 446 x 133 x 305 mm 3 height units Installation options 19 rack mounting Desktop operation Four point mounting Design of the mounting bracket for use on ships Dimensions without brackets for 19 rack moun...

Страница 82: ...ms Redundancy mechanism Reconfiguration times in ms HRP 300 Standby link 300 MRP 200 Table 8 3 Full wire speed switching Number of frames per second At a frame length of At 100 Mbps At 1000 Mbps For 10 Gbps 148810 1488095 14880952 64 bytes 84459 844595 8445946 128 bytes 45290 452899 4528986 256 bytes 23496 234962 2349664 512 bytes 11973 119732 1197318 1024 bytes 9615 96154 961538 1280 bytes 8127 8...

Страница 83: ...SCALANCE XR 500 Operating Instructions 05 2014 A5E03275845 05 83 Dimension drawings 9 9 1 SCALANCE XR524 8C View from front and above Dimensions are specified in mm ...

Страница 84: ...Dimension drawings 9 2 SCALANCE XR528 6M SCALANCE XR 500 84 Operating Instructions 05 2014 A5E03275845 05 9 2 SCALANCE XR528 6M View from front and above Dimensions are specified in mm ...

Страница 85: ...Dimension drawings 9 3 SCALANCE XR552 12M SCALANCE XR 500 Operating Instructions 05 2014 A5E03275845 05 85 9 3 SCALANCE XR552 12M View from front and above Dimensions are specified in mm ...

Страница 86: ...formation on the construction of the mounting brackets in the section Technical data Page 75 Note Different mounting brackets For the SCALANCE XR524 8C the mounting brackets for left and right are identical For SCALANCE XR528 6M and SCALANCE XR552 12M you require different mounting brackets The mounting brackets on one side are identical but the mounting brackets for left and right are different N...

Страница 87: ...wings 9 4 Mounting brackets for use on ships SCALANCE XR 500 Operating Instructions 05 2014 A5E03275845 05 87 Mounting brackets for a SCALANCE XR524 8C View from the front top and side Dimensions are specified in mm ...

Страница 88: ...nting brackets for use on ships SCALANCE XR 500 88 Operating Instructions 05 2014 A5E03275845 05 Mounting bracket for a SCALANCE XR528 6M Mounting bracket left View from the front top and side left Dimensions are specified in mm ...

Страница 89: ...on drawings 9 4 Mounting brackets for use on ships SCALANCE XR 500 Operating Instructions 05 2014 A5E03275845 05 89 Mounting bracket right View from the front top and side right Dimensions are specified in mm ...

Страница 90: ...ting brackets for use on ships SCALANCE XR 500 90 Operating Instructions 05 2014 A5E03275845 05 Mounting bracket for a SCALANCE XR552 12M Mounting bracket left View from the front top and side left Dimensions are specified in mm ...

Страница 91: ...on drawings 9 4 Mounting brackets for use on ships SCALANCE XR 500 Operating Instructions 05 2014 A5E03275845 05 91 Mounting bracket right View from the front top and side right Dimensions are specified in mm ...

Страница 92: ...Dimension drawings 9 4 Mounting brackets for use on ships SCALANCE XR 500 92 Operating Instructions 05 2014 A5E03275845 05 ...

Страница 93: ...en granted for your product by the markings on the type plate EC directives SIMATIC NET products meet the requirements and aims of the following EC directives EMC directive electromagnetic compatibility The SIMATIC NET products described in these operating instructions meet the requirements of EC directive 2004 108 EC Electromagnetic Compatibility for the following areas of application Field of ap...

Страница 94: ...Industrial Ethernet System Manual Industrial Ethernet PROFINET Passive network components System Manual You will find information on the system manuals in the section Introduction Page 5 in Further documentation EMC Installation Guidelines configuration manual 60612658 http support automation siemens com WW view en 60612658 Working on the device To protect the device from electrostatic discharge p...

Страница 95: ...on Use of subasseblies modules in a Zone 2 Hazardous Area You will find this document on the data medium that ships with some devices on the Internet pages of Siemens Industry Online Support http support automation siemens com WW view en Enter the document identification number C234 as the search term SIMATIC NET products meet the requirements of the EC directive 94 9 EC Equipment and Protective D...

Страница 96: ...art 0 Equipment General requirements Note Only variants with 24 VDC power supply meet the requirements of this approval FM The product meets the requirements of the standards Factory Mutual Approval Standard Class Number 3611 FM Hazardous Classified Location Electrical Equipment Non Incendive Class I Division 2 Groups A B C D T4 and Non Incendive Class I Zone 2 Group IIC T4 Note Only variants with...

Страница 97: ...ants with 24 VDC power supply meet the requirements of this approval EU declaration of conformity You will find EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support http support automation siemens com WW view en 33118389 134200 10 1 FDA and IEC marks The following devices meet the FDA and IEC requirements listed below Device Fulfills FDA and IEC ...

Страница 98: ...ability in operation Device IEC 60068 2 6 vibration IEC 60068 2 6 vibration IEC 60068 2 27 shock 5 9 Hz 3 5 mm 9 150 Hz 1 g 1 octave min 20 sweeps 10 58 Hz 0 075 mm 85 150 Hz 1 g 1 octave min 20 sweeps 15 g 11 ms duration 6 shocks per axis SCALANCE XR524 8C SCALANCE XR528 6M SCALANCE XR552 12M When rack mounted with four securing points ...

Страница 99: ...mode 16 19 22 Door in housing 68 70 Dummy cover 12 38 F Factory defaults 16 Factory settings 16 36 73 Fan unit 12 15 67 Fault error status 19 58 Filter frame 12 68 71 Filter pad 12 68 70 Firmware 19 72 Four point mounting 31 34 Front terminal 33 Functional ground 63 G Glossary 7 Grounding 63 Grounding bolt 63 H Handle 38 I IEC plug 51 Installation location 9 Interface 12 K KEY PLUG 14 24 25 L Laye...

Страница 100: ...lug 41 41 SELECT SET button 16 20 72 73 Serial interface 59 SFP 12 13 40 41 SFP SFP transceiver Notes on deinstallation 41 Removing 41 SFP slot 41 41 SFP transceiver 31 40 41 SFP SFP transceivers Inserting 41 SFP 12 14 40 41 SFP slot 31 41 41 SFP transceiver 31 40 41 Ship 34 Signaling contact 19 57 SIMATIC NET glossary 7 SIMATIC NET manual 6 Slot 41 Slot number 12 37 Startup phase 17 19 73 Switch ...

Отзывы: