If you do not select an interface, the function is enabled for all available interfaces.
Result
The settings for monitoring the physical network connections have been configured.
Further notes
You display the setting with the
show events faults config
command.
You disable the function with the
no link
command.
12.1.8.11
no link
Description
With this command, you disable the monitoring of the physical network connections for cable
breaks or for pulling of the connector.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no {up|down}[{<interface-type><interface-id>}]
The parameters have the following meaning:
Parameter
Description
Range of values / note
up
The message when establishing a connection is dis‐
abled
-
down
The message when a connection is down is disabled -
interface-
type
Type or speed of the interface
Enter a valid interface.
interface-
id
Module no. and port no. of the interface
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
If you do not select an interface, the function is disabled for all available interfaces.
Diagnostics
12.1 Event and fault handling
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
564