The parameters have the following meaning:
Parameter
Description
interface-type
Specifies the interface type for the first ring port
interface-id
Specifies the number of the interface for the first ring port
interface-type
Specifies the interface type for the second ring port
interface-id
Specifies the number of the interface for the second ring port
For information on names of addresses and interfaces, refer to the section "Addresses and
Note
Differing port addresses
The first and second port must be configured on different interfaces.
Result
The ports of the ring redundancy are configured.
8.4.6.4
standby connection-name
Description
With this command, you assign a name to the standby connection on the device.
Requirement
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call up the command with the following parameters:
standby connection-name <string(32)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
<string(32)>
Name of the connection
max. 32 characters
Result
The standby connection is assigned a name.
Layer 2 management protocols
8.4 Ring redundancy and standby connection
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
403