Requirement
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
fmp rx-power [req { <integer(0-0)> | - <integer(1-40)>}] [dem
{ <integer(0-0)> | - <integer(1-40)>}]
The parameters have the following meaning:
Parameter
Description
Range of values / note
req
Specify the value at which you are informed of the de‐
terioration of the received power by a message of the
severity level "Warning"
0 ... -40 dBm
The default value depends on the relevant
pluggable transceiver.
If you enter the value "0", the received
power is not monitored.
dem
Specify the value at which you are informed of the de‐
terioration of the received power by a message of the
severity level "Critical"
0 ... -40 dBm
The default value depends on the relevant
pluggable transceiver.
If you enter the value "0", the received
power is not monitored.
Result
The limits for monitoring the received power are defined.
Further notes
You enable this function with the
fmp
command.
You disable this function with the
no fmp
command.
You display the status of this function and other information with the and
show fmp limit
commands.
You define the limit values for the power loss with the command
fmp power-loss
.
Diagnostics
12.2 FMP
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
572
Configuration Manual, 07/2017, C79000-G8976-C361-06