![Siemens SCALANCE X-300 Скачать руководство пользователя страница 303](http://html.mh-extra.com/html/siemens/scalance-x-300/scalance-x-300_configuration-manual_379386303.webp)
Configuration using Web Based Management and Command Line Interface
4.7 The Router menu (SCALANCE X414-3E)
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
303
Authent. Type
Authentication method selected on this interface. The following are available:
●
none: no authentication
●
simple: authentication using a password
●
MD5: authentication with keyed MD5 method
Events
Number of changes to the interface status.
Creating a new OSPFv2 interface
With the "New Entry" button in the "OSPFv2 Interfaces" dialog, you can configure a new IP
interface for OSPF.
Note
Before an interface can be created as an OSPF interface, it must first be created as an IP
subnet.
Note
Take particular care when selecting the parameters. A correct neighbor-neighbor relationship
is possible only when identical parameters are configured on all routers of an IP subnet.
Otherwise, the impression is that the routers cannot see each other.
Figure 4-142 OSPFv2 Interface Configuration
IP Address