Configuration using Web Based Management and Command Line Interface
4.4 The Agent menu
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
109
Command
Description
Comment
setec [event]
<E|D> <E|D>
<E|D> <E|D>
Specifies how an IE switch reacts to system events.
The following abbreviations are available for the event parameter:
•
CW
Cold/Warm start
•
LC
Link Change
•
AF
Authentication Failure
•
RA
RMON Alarm
•
PC
Power Change
•
RC
RM State Change
•
SC
Standby State Change
•
FC
Fault State Change
•
RS
STP/RSTP Change
•
LD
Loop Detection State Change
•
PA
Port Auth State Change
•
VE
VRRP State Change
(X414 only)
•
FO
Fiber Optic Diagnostics
If an event is specified, the configured actions are formed for each
event.
The four parameters that follow <E> or <D> configure the reactions
of the IE switch in the order:
•
•
Trap
•
Entry in the log table
•
Entry on the Syslog server
Example:
•
setec LC E D D D
Only sends an E-mail if there is a Link Change.
Administrator
only.