Configuration using Web Based Management and Command Line Interface
4.4 The Agent menu
SCALANCE X-300 / X-400
108
Configuration Manual, 10/2014, C79000-G8976-C187-22
Signaling Contact Control
With this drop-down list, you can specify how the signaling contact works:
●
conventional
Default setting for the signaling contact. An error/fault is displayed by the fault LED and
the signaling contact opens. When the error/fault state no longer exists, the fault LED
goes off and the signaling contact closes.
●
aligned
The way the signaling contact works depends on the error/fault that has occurred. The
signaling contact can be opened or closed as required by user actions.
Close Signaling Contact
Select this check box if you want to close the signaling contact.
Note
The setting of the "Close Signaling Contact" check box is only effective if the "aligned"
setting was selected in the "Signaling Contact Control" drop-down list.
Syntax of the Command Line Interface
Table 4- 26 Agent Event Configuration - CLI\AGENT\EVENT>
Command
Description
Comment
info
Shows the current event configuration.
-