If you call the command without parameters, you disable the spanning tree function. The
configured time settings are retained.
If you call the
restart factory
command, the system restarts with the factory configuration
settings All rime settings are reset.
The default values are as follows:
Parameter
Default value
forward-time
15 seconds
hello-time
2 seconds
max-age
20 seconds
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no spanning-tree{forward-time|hello-time|max-age}
The parameters have the following meaning:
Parameter
Description
forward-time
Time after which a port changes its spanning tree status from "Blocking" to
"Forwarding"
hello-time
Time after which the bridge sends its configuration frames (BPDUs)
max-age
Time after which the information of the BPDUs becomes invalid
Result
The selected setting for the time is reset to the default value.
Further notes
You configure the time with the
spanning-tree
command (time settings).
You display these settings and other information with the commands that start with
show
spanning-tree ...
.