Syntax
Call up the command with the following parameters:
ntp server { ipv4 <ip_addr> | fqdn-name <Fully Qualified Domain
Name(100)> | ipv6 <ip6_addr> } [port { <1025-36564> | default}] [poll
<seconds(64-1024)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
id
Number of the NTP server.
1 … 4
ipv4
Keyword for an IPv4 address
-
ip_addr
Value for the IPv4 address of the time
server
Enter a valid IPv4 address.
fqdn-name
Keyword for a domain name
-
FQDN
Domain name (Fully Qualified Domain
Name)
Maximum of 100 characters
If you have stored a suitable do‐
main name, you can specify a host
name.
ipv6
Keyword for an IPv6 address
-
ip6_addr
Value for the IPv6 address of the time
server
Enter a valid IPv6 address.
port
UDP port of the time server
1025 … 36564
default
Default value for the UDP port
123
poll
Keyword for the time after which the
time of day is requested again
-
seconds
Value for the time in seconds
64 … 1024
For information on identifiers of addresses and interfaces, refer to the section "Addresses and
interface identifiers (Page 29)".
Result
The connection to a server is configured on the NTP client.
Further notes
You delete the connection to a server with the
no ntp server
command.
You store a domain name with the
ip domain name
or
domain name
command.
6.2.3.2
no ntp server
Description
With this command, you delete the connection to a server on the NTP client.
System time
6.2 NTP client
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
175