UMN:CLI User Manual
SURPASS hiD 6615 S223/S323 R1.5
224 A50010-Y3-C150-2-7619
To enable/disable self loop detection, use the following command.
Command Mode
Description
self-loop-detect
{
enable
|
dis-
able
}
Bridge Enables/disables
self loop detection function.
To display a configuration for BPDU, use the following command.
Command Mode
Description
show self-loop-detect
Shows status of self loop detection and a port where
loop is happed.
show self-loop-detect
{
all
|
PORTS
}
Enable
Global
Bridge
Shows self loop detection status on specified ports:
all: all the ports
PORTS: selected port
8.3.9.8
Displaying BPDU Configuration
To display the configuration for BPDU, use the following command.
Command Mode
Description
show stp mst
MSTID-RANGE
{
all
|
PORTS
} [
detail
]
show stp mst
MSTID-RANGE
all
[
detail
]
show stp mst
MSTID-RANGE
PORTS
[
detail
]
Shows a configuration for BPDU for STP, RSTP and
MSTP.
show stp pvst VLAN-RANGE
[
all
|
PORTS
] [
detail
]
Enable
Global
Bridge
Shows a configuration for BPDU for PVSTP and
PVRSTP.