User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5
A50010-Y3-C150-2-7619 113
7.1.9.2 Default
Alarm
Severity
To configure a priority of alarm, use the following command.
Command Mode
Description
snmp alarm-severity default
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Global
Configures the priority of alarm.
(default: minor)
7.1.9.3 Alarm
Severity
Criterion
You can set an alarm severity criterion to make an alarm be shown only in case of se-
lected severity or higher. For example, if an alarm severity criterion has been set to
major
,
you will see only an alarm whose severity is
major
or
critical
.
To configure alarm-severity criteria in CLI, use the following command.
Command Mode
Description
snmp alarm-severity criteria
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Global
Configures the severity criterion.
(default: warning)
The order of alarm severity is
critical
>
major
>
minor
>
warning
>
intermediate
.
The alarm severity option is valid only in ACI-E.
i
!