RUGGEDCOM WIN5237
Installation Guide
Chapter 5
Certification
Environmental Type Tests
35
Test
Description
Test Levels
Frequency Range: 5 to 62 Hz, 62 to 200 Hz
3 Axes
Duration: 3x5 sweep
Random Vibration (Class 4M5)
ASD: 0.04 m²/s³
12 to 12 dB/oct
Frequency Range: 5 to 10 Hz, 10 to 50, 50 to 100 Hz
3 axes, 30 min per axes
IEC 60068-2-64
Random Vibration
ASD: 1 m²/s³
-3 dB/oct
Frequency Range: 5 to 20 Hz, 20 to 200 Hz
3 axes, 30 min per axes
Shock (Class 4M5)
Spectrum: Half sine
Duration: 11 ms
Accelerator: 50 m/s²
100 shocks in each direction
IEC 60068-2-29
Shock
Spectrum: Half sine
Duration: 6 ms
Accelerator: 180 m/s²
100 shocks in each direction
IEC 60068-2-32
Nebs: GR63
Free Fall
Height: 1 m (3.3 ft)
One fall on 3 faces, 3 edges and 4 corners
30 °C (86 °F) @ 90 to 100% for 2 cycles
IEC 60068-2-30
Humidity (Cycling)
40 °C (104 °F) @ 90 to 100% for 2 cycles