Modules
4.2 Available Modules
IMPORTANT
Electrical hazard – risk of power failure
Power fluctuations or irregular shut downs may occur if the total power consump-
tion of all installed modules exceeds the power budget of the device.
Power Budget
Total Power Budget for the Device
50 W
Power Budget for Line Modules (@ 9 W Used For the System)
41.5 W
Module Power Consumption
Module Type
Power Consumption
RUGGEDCOM APE1808
12 W
RUGGEDCOM APE1402
10 W
RUGGEDCOM APE1404
10 W
2-Port Fiber Optic (FG50 + SFPs)
7 W
6-Port Fiber Optic (6FX50)
7 W
WAN Cell (3G, LTE)
7 W
2-Port Copper (M12, RJ45)
4 W
4-Port Copper (M12, RJ45)
5 W
6-Port Copper (M12, RJ45)
5 W
WAN T1, E1
3 W
Serial (S01)
3 W
Example
A device with the following modules installed would exceed the power budget for
line modules (41.5 W):
Module
Quantity
Consumption
RUGGEDCOM APE1808
2
24 W
2-Port Fiber Optic (FG50 + SFPs)
2
14 W
6-Port Copper (M12, RJ45)
1
5 W
Total Consumption
43 W
4.2
Available Modules
The following is a list of all power and line modules available for use in the RUGGED-
COM RX1501. For more information about individual modules, refer to the
RUGGED-
COM RX1500 Series Modules Catalog
[https://support.industry.siemens.com/cs/ca/-
en/view/109747072]
.
26
RUGGEDCOM RX1501
Installation Manual, 05/2020, C79000-G8976-1054-17
All manuals and user guides at all-guides.com