Chapter 6
Certification
RUGGEDCOM RS900W
Installation Guide
32
EMC and Environmental Type Tests
Test
Description
Test Levels
Severity Levels
DC Power Ports
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
3
AC Power Ports
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
4
Signal Ports
10 V
3
DC Power Ports
10 V
3
AC Power Ports
10 V
3
IEC 61000-4-6
Induced (Conducted) RFI
Earth
Ground Ports
10 V
3
IEC 61000-4-8
Magnetic Field
Enclosure Ports
40 A/m Continuous
1000 A/m for 1 s
IEC 61000-4-29
Voltage Dips and Interrupts
DC Power Ports
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
IEC 61000-4-11
Voltage Dips and Interrupts
AC Power Ports
100% for 5 Periods
100% for 50 Periods
Signal Ports
2.5 kV Common Mode @ 1 MHz
1 kV Differential Mode @ 1 MHz
3
DC Power Ports
2.5 kV Common Mode @ 1 MHz
1 kV Differential Mode @ 1 MHz
3
IEC 61000-4-12
Damped Oscillatory
AC Power Ports
2.5 kV Common Mode @ 1 MHz
1 kV Differential Mode @ 1 MHz
3
Signal Ports
30 V Continuous
300 V for 1 s
4
IEC 61000-4-16
Mains Frequency Voltage
DC Power Ports
30 V Continuous
300 V for 1 s
4
IEC 61000-4-17
Ripple on DC Power Supply
DC Power Ports
10%
3
Signal Ports
2 kV (Failsafe Relay Output)
DC Power Ports
1.5 kV
Dielectric Strength
AC Power Ports
2 kV
Signal Ports
5 kV (Failsafe Relay Output)
DC Power Ports
5 kV
IEC 60255-5
HV Impulse
AC Power Ports
5 kV
Содержание RUGGEDCOM RS900W
Страница 4: ...RUGGEDCOM RS900W Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS900W Installation Guide x Customer Support ...
Страница 14: ...Chapter 1 Introduction RUGGEDCOM RS900W Installation Guide 4 Description ...
Страница 32: ...Chapter 3 Communication Ports RUGGEDCOM RS900W Installation Guide 22 Channel Allocations for IEEE 802 11b g ...
Страница 44: ...Chapter 6 Certification RUGGEDCOM RS900W Installation Guide 34 EMC and Environmental Type Tests ...