Technical Specifications
Fiber Optic Ethernet Port Specifications
25
Isolation
i
1.5 kV
e
Auto-negotiating.
f
Shielded or unshielded.
g
Auto-crossover and auto-polarity.
h
Typical distance. Dependent on the number of connectors and splices.
i
RMS 1 minute.
Section 4.4
Fiber Optic Ethernet Port Specifications
The following details the specifications for fiber Ethernet ports that can be ordered with the RUGGEDCOM
RS900W.
NOTE
• All optical power numbers are listed as dBm averages. To convert from average to peak add 3 dBm.
To convert from peak to average, subtract 3 dBm.
• Maximum segment length is greatly dependent on factors such as fiber quality, and the number
of patches and splices. Consult a Siemens sales associate when determining maximum segment
distances.
Tx (dBm)
Mode
Connector
Type
Tx λ (nm)
j
Cable
Type (μm)
Minimum
Maximum
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(km)
j
Power
Budget
(dB)
62.5/125
1300
-19
-14
-31
-14
2
12
MM
ST
50/125
1300
-22.5
-14
-31
-14
2
8.5
62.5/125
1300
-19
-14
-31
-14
2
12
MM
SC
50/125
1300
-22.5
-14
-31
-14
2
8.5
MM
MTRJ
62.5/125
1300
-19
-14
-31
-14
2
12
SM
ST
9/125
1300
-15
-8
-32
-3
20
17
SM
SC
9/125
1300
-15
-8
-31
-7
20
16
SM
LC
9/125
1300
-15
-8
-34
-7
20
19
SM
SC
9/125
1300
-5
0
-34
-3
50
29
SM
LC
9/125
1300
-5
0
-35
3
50
30
SM
SC
9/125
1300
0
5
-37
0
90
37
SM
LC
9/125
1300
0
5
-37
0
90
37
MM
LC
50/125
1300
-22.5
-14
-31
-14
2
8.5
j
Typical.
Содержание RUGGEDCOM RS900W
Страница 4: ...RUGGEDCOM RS900W Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS900W Installation Guide x Customer Support ...
Страница 14: ...Chapter 1 Introduction RUGGEDCOM RS900W Installation Guide 4 Description ...
Страница 32: ...Chapter 3 Communication Ports RUGGEDCOM RS900W Installation Guide 22 Channel Allocations for IEEE 802 11b g ...
Страница 44: ...Chapter 6 Certification RUGGEDCOM RS900W Installation Guide 34 EMC and Environmental Type Tests ...