RUGGEDCOM RS900W
Installation Guide
Chapter 2
Installing the Device
Connecting to the Device
15
IMPORTANT!
The serial console port is intended to be used only as a temporary connection during initial
configuration or troubleshooting, and should only be used in a safe area (as defined by IEC 60079-0,
Edition 6.0).
Use the following settings to connect to either port:
Speed
57600 Mbps
Data Bits
8
Stop Bit
1
Parity
None
Flow Control
Off
Terminal ID
VT100
Speed
57600 Mbps
The serial console port implements RS232 DCE (Data Communication Equipment) on a DB9 connector. The
following is the pin-out for the port:
1
5
9
6
Figure 9: Serial DB9 Console Port
Pin
Name
Description
1
a
Reserved (Do Not Connect)
2
TX
Transmit Data
3
RX
Receive Data
4
a
Reserved (Do Not Connect)
5
GND
Signal Ground
6
a
Reserved (Do Not Connect)
7
b
Reserved (Do Not Connect)
8
b
Reserved (Do Not Connect)
9
Reserved (Do Not Connect)
a
Connected internally.
b
Connected internally.
Communication Ports
Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM
ROS console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM
.
Содержание RUGGEDCOM RS900W
Страница 4: ...RUGGEDCOM RS900W Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS900W Installation Guide x Customer Support ...
Страница 14: ...Chapter 1 Introduction RUGGEDCOM RS900W Installation Guide 4 Description ...
Страница 32: ...Chapter 3 Communication Ports RUGGEDCOM RS900W Installation Guide 22 Channel Allocations for IEEE 802 11b g ...
Страница 44: ...Chapter 6 Certification RUGGEDCOM RS900W Installation Guide 34 EMC and Environmental Type Tests ...