Chapter 4
Technical Specifications
RUGGEDCOM RS900W
Installation Guide
24
Failsafe Relay Specifications
Input Range
Power Supply Type
Minimum
Maximum
Internal
Fuse Rating
c
Isolation
Maximum Power
Consumption
d
48
37 VDC
72 VDC
3.15 A(T)
1.5 kVDC
10 W
c
(T) denotes time-delay fuse.
d
Power consumption varies based on configuration.
Section 4.2
Failsafe Relay Specifications
Hazardous Environments
Maximum Switching Voltage
Rated Switching Current
Isolation
30 VDC
1 A
80 VDC
30 VAC
0.3 A
1500 V
rms
for 1 minute
Non-Hazardous Environments
Maximum Switching Voltage
Rated Switching Current
Isolation
30 VDC
2 A, 60 W
125 VDC
0.24 A, 30 W
125 VAC
0.5 A, 62.5 W
220 VDC
0.24 A, 60 W
250 VAC
0.25 A, 62.5 W
1500 V
rms
for 1 minute
Section 4.3
Copper Ethernet Port Specifications
The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM
RS900W.
Speed
e
10/100Base-TX
Connector
RJ45
Duplex
e
FDX/HDX
Cable Type
f
> CAT 5
Wiring Standard
g
TIA/EIA T568A/B
Maximum Distance
h
100 m (328 ft)
Содержание RUGGEDCOM RS900W
Страница 4: ...RUGGEDCOM RS900W Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS900W Installation Guide x Customer Support ...
Страница 14: ...Chapter 1 Introduction RUGGEDCOM RS900W Installation Guide 4 Description ...
Страница 32: ...Chapter 3 Communication Ports RUGGEDCOM RS900W Installation Guide 22 Channel Allocations for IEEE 802 11b g ...
Страница 44: ...Chapter 6 Certification RUGGEDCOM RS900W Installation Guide 34 EMC and Environmental Type Tests ...