RUGGEDCOM RS900GP
Installation Guide
Chapter 6
Certification
EMC and Environmental Type Tests
35
Test
Description
Test Levels
Severity Levels
Signal Ports
30 V Continuous
4
IEC 61000-4-16
Mains Frequency Voltage
DC Power Ports
30 V Continuous, 300 V for 1s
4
IEC 61000-4-17
Ripple on DC Power Supply
DC Power Ports
± 15%
4
Signal Ports
2 kV (Fail-Safe Relay output)
IEC 60255-5
Dielectric Strength
DC Power Ports
1.5 kV
Signal Ports
5 kV (Fail-Safe Relay output)
IEC 60255-5
HV Impulse
DC Power Ports
5 kV
EMC Immunity Type Tests per IEEE 1613
NOTE
The RUGGEDCOM RS900GP meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper Ports. Class 1 allows for temporary communication loss, while Class 2 requires
error-free and interrupted communications.
Description
Test Levels
Enclosure Contact
± 8 kV
ESD
Enclosure Air
± 15 kV
Radiated RFI
Enclosure Ports
35 V/m
Signal Ports
± 2 kV @ 2.5 kHz
DC Power Ports
± 1.5 kV
Fast Transient
Earth Ground Ports
± 2 kV
Signal Ports
2.2 kV Common Mode @ 1 MHz
Oscillatory
DC Power Ports
2.2 kV Common and Differential Mode @ 1 MHz
Signal Ports
5 kV (Failsafe Relay)
HV Impulse
DC Power Ports
5 kV
Signal Ports
2 kV (Failsafe Relay)
Dielectric Strength
DC Power Ports
1.5 kV
Environmental Type Tests
Test
Description
Test Levels
Severity Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40 °C (-40 °F), 16 Hours
IEC 60068-2-2
Dry Heat
Test Bd
85 °C (185 °F), 16 Hours
IEC 60255-21-1
Vibration
2g @ 10-150 Hz
Class 2
IEC 60255-21-2
Shock
30g @ 11 ms
Class 2
Содержание RUGGEDCOM RS900GP
Страница 4: ...RUGGEDCOM RS900GP Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS900GP Installation Guide x Customer Support ...
Страница 14: ...Chapter 1 Introduction RUGGEDCOM RS900GP Installation Guide 4 Decommissioning and Disposal ...
Страница 24: ...Chapter 2 Installing the Device RUGGEDCOM RS900GP Installation Guide 14 Connecting Power ...
Страница 40: ...Chapter 5 Technical Specifications RUGGEDCOM RS900GP Installation Guide 30 Dimension Drawings ...
Страница 46: ...Chapter 6 Certification RUGGEDCOM RS900GP Installation Guide 36 EMC and Environmental Type Tests ...