Chapter 4
Communication Ports
RUGGEDCOM RS900GP
Installation Guide
20
PoE Ports
Standard
Power Budget
IEEE 802.3af
135 W
If the power input is less than what is required, to prevent exceeding the power budget, port priorities can be
set via the RUGGEDCOM ROS operating system to disable low priority ports when demand is too high. Ports can
also be enabled/disabled and placed on a power schedule to conserve power. For more information, refer to the
RUGGEDCOM ROS User Guide
for the device.
For information about connecting a power source, refer to
Section 2.7, “Connecting Power”
.
LEDs
Each PoE port features an LED that indicates the port's power and link/activity state.
2
1
2
1
Figure 15: RJ45 Port LEDs
1.
Link/Activity LED
2.
Power State LED
LED
State
Description
Green (Solid)
Link established
Green (Blinking)
Link activity
Link/Activity
Off
No link detected
Yellow (Solid)
Power provided
Yellow (Blinking)
Searching for load
Power State
Off
No power or port
disabled
Pin-Out
The pin-out for the PoE ports is as follows:
1
8
Figure 16: RJ45 Ethernet Port Pin Configuration
Pin
Name
Description
1
RX+
Receive Data+
2
RX-
Receive Data-
3
TX+
Transmit Data+
4
Reserved (Do Not Connect)
5
Reserved (Do Not Connect)
6
TX-
Transmit Data-
7
Reserved (Do Not Connect)
8
Reserved (Do Not Connect)
Specifications
For specifications on the available PoE ports, refer to
Section 5.4, “Copper Ethernet Port Specifications”
For PoE power output specifications, refer to
Содержание RUGGEDCOM RS900GP
Страница 4: ...RUGGEDCOM RS900GP Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS900GP Installation Guide x Customer Support ...
Страница 14: ...Chapter 1 Introduction RUGGEDCOM RS900GP Installation Guide 4 Decommissioning and Disposal ...
Страница 24: ...Chapter 2 Installing the Device RUGGEDCOM RS900GP Installation Guide 14 Connecting Power ...
Страница 40: ...Chapter 5 Technical Specifications RUGGEDCOM RS900GP Installation Guide 30 Dimension Drawings ...
Страница 46: ...Chapter 6 Certification RUGGEDCOM RS900GP Installation Guide 36 EMC and Environmental Type Tests ...