Chapter 5
Technical Specifications
RUGGEDCOM RS900GP
Installation Guide
24
Failsafe Alarm Relay Specifications
Section 5.3
Failsafe Alarm Relay Specifications
NOTE
The following specifications are for Class-2 circuits only.
Maximum Switching Voltage
Rated Switching Current
Isolation
30 VDC
1 A
80 VDC
30 VAC
0.3 A
1500 V
rms
for 1 minute
Section 5.4
Copper Ethernet Port Specifications
The following details specifications for all standard and optional fixed copper Ethernet ports that can be ordered
with the RUGGEDCOM RS900GP. For more information about the SFP ports, refer to
NOTE
• Maximum segment length is greatly dependent on factors such as fiber quality, and the number
of patches and splices. Consult a Siemens Sales associate when determining maximum segment
distances.
• All optical power numbers are listed as dBm averages.
• F51 transceivers are rated for -40 to 85 °C (-40 to 185 °F).
Connector
Duplex
b
Cable Type
c
Wiring Standard
d
Maximum Distance
e
Isolation
RJ45 (PoE
and Non-PoE)
FDX/HDX
> CAT-5
TIA/EIA T568A/B
100 m (328 ft)
1.5 kV
micro-D
FDX/HDX
> CAT-5
TIA/EIA T568A/B
100 m (328 ft)
1.5 kV
b
Auto-Negotiating.
c
Shielded or unshielded.
d
Auto-crossover and auto-polarity.
e
Typical distance. Dependent on the number of connectors and splices.
Section 5.5
Fiber Optic Ethernet Port Specifications
The following details specifications for all optional fixed fiber optic Ethernet ports that can be ordered with the
RUGGEDCOM RS900GP. For more information about the SFP ports, refer to
Содержание RUGGEDCOM RS900GP
Страница 4: ...RUGGEDCOM RS900GP Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS900GP Installation Guide x Customer Support ...
Страница 14: ...Chapter 1 Introduction RUGGEDCOM RS900GP Installation Guide 4 Decommissioning and Disposal ...
Страница 24: ...Chapter 2 Installing the Device RUGGEDCOM RS900GP Installation Guide 14 Connecting Power ...
Страница 40: ...Chapter 5 Technical Specifications RUGGEDCOM RS900GP Installation Guide 30 Dimension Drawings ...
Страница 46: ...Chapter 6 Certification RUGGEDCOM RS900GP Installation Guide 36 EMC and Environmental Type Tests ...