![Siemens RUGGEDCOM RS900F Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/siemens/ruggedcom-rs900f/ruggedcom-rs900f_installation-manual_377336047.webp)
RUGGEDCOM RS900F
Installation Guide
Chapter 6
Certification
EMC and Environmental Type Tests
37
Description
Test Levels
DC Power Ports
5 kV
AC Power Ports
5 kV
Signal Ports
2 kV (Failsafe Relay)
DC Power Ports
1.5 kV
Dielectric Strength
AC Power Ports
2 kV
Environmental Type Tests
Test
Description
Test Levels
Severity Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40 °C (-40 °F), 16 Hours
IEC 60068-2-2
Dry Heat
Test Bd
85 °C (185 °F), 16 Hours
IEC 60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db
95% (Non-Condensing),
55 °C (131 °F), 6 Cycles
IEC 60255-21-1
Vibration
2 g @ 10 to 150 Hz
Class 2
IEC 60255-21-2
Shock
30 g @ 11 ms
Class 2