RUGGEDCOM RS900F
Installation Guide
Chapter 2
Installing the Device
Connecting Low DC Power
15
±
±
±
±
1
3
1
2
2
4
Figure 7: Terminal Block Wiring – Dual DC Power Supply Inputs
1.
Positive Terminal
2.
Negative Terminal
3.
Surge Ground Terminal
4.
Braided Ground Cable
3. Connect the negative wire from the power source to the negative/neutral (-/N) terminal on the terminal block.
4. Connect the ground wire from the power source to the chassis groun terminal on the terminal block.
Section 2.6.2
Connecting Low DC Power
RUGGEDCOM RS900F's equipped with 24 or 48 V power supply inputs feature reverse polarity protection and dual
power supply inputs allowing the device to accept redundant connections to a single DC power supply.
To connect a low DC power supply to the device, do the following:
NOTE
Torque all terminal connections to 0.6 N·m (5 lbf-in).
1. Secure the power terminal block to the device.
2. Connect the positive wire from the power source to the positive terminal on the terminal block.
Содержание RUGGEDCOM RS900F
Страница 4: ...RUGGEDCOM RS900F Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS900F Installation Guide x Customer Support ...
Страница 16: ...Chapter 1 Introduction RUGGEDCOM RS900F Installation Guide 6 Tamper Evident Security Seals ...
Страница 28: ...Chapter 2 Installing the Device RUGGEDCOM RS900F Installation Guide 18 Connecting Low DC Power ...
Страница 34: ...Chapter 4 Communication Ports RUGGEDCOM RS900F Installation Guide 24 Fiber Optic Ethernet Ports ...
Страница 48: ...Chapter 6 Certification RUGGEDCOM RS900F Installation Guide 38 EMC and Environmental Type Tests ...