Installing Device
2.6.2 Connecting External PoE Power
7. Connect the ground terminal on the power source to the chassis ground
terminal on the device. For more information, refer to
DANGER
Electrocution hazard – risk of death, serious personal injury and/or damage
to the device
Make sure the supplied terminal block cover is always installed before the
device is powered.
8. Install the terminal block cover.
2.6.2
Connecting External PoE Power
The RUGGEDCOM RS416PF supports up to four 10/100Base-TX Power-over-Ethernet
(POE) Ports that require power from an external source.
Note
For IEC 61850 compliance, use an IEC 61850 compliant PoE power supply with
power cabling no longer than 3 m (118 in).
Otherwise, Siemens recommends using the RUGGEDCOM RPS1300 switch-mode
AC power supply. For more information about this power supply, refer to
support.industry.siemens.com/cs/ww/en/view/109478699
.
To connect an external power supply for the PoE ports, do the following:
NOTICE
Electrical hazard – risk of damage to equipment
Only connect the external PoE power supply to the terminals 5 and 7.
1. Remove the terminal block cover.
2. If a screw-type terminal block is installed, remove the screws from terminals
5 and 7. Use these screws along with #6 ring lugs to secure the wires to the
terminal block.
18
RUGGEDCOM RS416PF
Installation Manual, 04/2021, C79000-G8976-1355-04
Содержание RUGGEDCOM RS416PF
Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM RS416PF Installation Manual 04 2021 C79000 G8976 1355 04 ...
Страница 17: ...Introduction 1 6 3 IEEE 1588 Support 8 RUGGEDCOM RS416PF Installation Manual 04 2021 C79000 G8976 1355 04 ...