17
Input Range
Power Supply Type
Minimum
Maximum
Isolation
Minimum
Power Required
DC
45 VDC
57 VDC
1.5 kVAC/2.2 kVDC
75 W
Connecting the External Power Supply
To connect an external power supply for the PoE ports, do the following:
CAUTION!
Electrical hazard – risk of damage to equipment. Only connect the external PoE power supply to the
terminals 5 and 7.
1. Remove the terminal block cover.
2. If a screw-type terminal block is installed, remove the screws from terminals 5 and 7. Use these screws along
with #6 ring lugs to secure the wires to the terminal block.
3. Connect the positive wire from the power source to terminal 5 (+/L) on the terminal block.
3
4
3
4
1
2
3
3
1
Figure 10: Terminal Block Wiring
1.
Screw-Type Terminal Block
2.
Pluggable Terminal Block
3.
Jumper
4.
Terminal 4 (Chassis Ground)
5.
Terminal 5 (+/L)
6.
Terminal 7 (-/N)
7.
Chassis Ground Terminal
4. Connect the negative wire from the power source to terminal 7 (-/N) on the terminal block.
5. If the external PoE power supply features a chassis ground connection, connect the ground terminal on the
power supply to terminal 4 on the terminal block.
DANGER!
Electrocution hazard – risk of death, serious personal injury and/or damage to the device. Make
sure the supplied terminal block cover is always installed before the device is powered.
6. Install the terminal block cover.
Содержание RUGGEDCOM RS416P
Страница 4: ...RUGGEDCOM RS416P Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS416P Installation Guide x Customer Support ...
Страница 18: ...Chapter 1 Introduction RUGGEDCOM RS416P Installation Guide 8 IEEE 1588 Support ...
Страница 30: ...Chapter 2 Installing Device RUGGEDCOM RS416P Installation Guide 20 Wiring Examples ...
Страница 48: ...Chapter 5 Technical Specifications RUGGEDCOM RS416P Installation Guide 38 Dimension Drawings ...