Chapter 2
Installing Device
RUGGEDCOM RS416P
Installation Guide
14
Grounding the Device
5
3
5
2
1
4
4
3
Figure 7: Failsafe Alarm Relay Wiring
1.
Screw-Type Terminal Block
2.
Pluggable Terminal Block
3.
Normally Open Terminal
4.
Common Terminal
5.
Normally Closed
Terminal
Section 2.5
Grounding the Device
The RUGGEDCOM RS416P chassis ground terminal uses a #6-32 screw. It is recommended to terminate the ground
connection with a #6 ring lug and torque it to 1.7 N·m (15 lbf·in).
2
1
3
Figure 8: Chassis Ground Connection
1.
Stainless Steel Stud
2.
#6-32 Screw
3.
#6 Ring Lug
Section 2.6
Connecting Power
The RUGGEDCOM RS416P supports a single high AC or low DC power supply, and a separate 48 VDC power supply
for PoE ports.