Chapter 2
Installing Device
RUGGEDCOM RS416P
Installation Guide
16
Connecting External PoE Power
4. Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block.
4
2
1
3
4
6
5
7
4
6
5
3
6
5
7
4
6
5
Figure 9: Terminal Block Wiring
1.
Screw-Type Terminal Block
2.
Pluggable Terminal Block
3.
Jumper
4.
Positive/Live (+/L) Terminal
5.
Negative/Neutral (-/N)
Terminal (-/N)
6.
Surge Ground Terminal
7.
Chassis Ground Terminal
5. Connect the negative wire from the power source to the negative/neutral (-/N) terminal on the terminal block.
6. Install the supplied metal jumper between terminals 2, 4 and 6 to connect the surge ground terminals to
the chassis ground terminal. The surge ground terminals are used as the ground conductor for all surge and
transient suppression circuitry internal to the unit.
7. Connect the ground terminal on the power source to the chassis ground terminal on the device. For more
information, refer to
Section 2.5, “Grounding the Device”
DANGER!
Electrocution hazard – risk of death, serious personal injury and/or damage to the device. Make
sure the supplied terminal block cover is always installed before the device is powered.
8. Install the terminal block cover.
Section 2.6.2
Connecting External PoE Power
The RUGGEDCOM RS416P supports up to four 10/100Base-TX Power-over-Ethernet (POE) Ports that require power
from an external source.
NOTE
For IEC 61850 compliance, use an IEC 61850 compliant PoE power supply with power cabling no
longer than 3 m (118 in).
External Power Supply Requirements
To support the
IEEE 802.3af
specification (15 W/port output), the external power supply must meet the following
requirements:
Содержание RUGGEDCOM RS416P
Страница 4: ...RUGGEDCOM RS416P Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS416P Installation Guide x Customer Support ...
Страница 18: ...Chapter 1 Introduction RUGGEDCOM RS416P Installation Guide 8 IEEE 1588 Support ...
Страница 30: ...Chapter 2 Installing Device RUGGEDCOM RS416P Installation Guide 20 Wiring Examples ...
Страница 48: ...Chapter 5 Technical Specifications RUGGEDCOM RS416P Installation Guide 38 Dimension Drawings ...