RUGGEDCOM ROS
User Guide
Chapter 3
Device Management
Clearing Cable Diagnostics
75
11
10
9
8
7
6
5
4
3
2
1
Figure 33: Cable Diagnostics Parameters Form
1.
Port Box
2.
State Options
3.
Runs Box
4.
Calib. Box
5.
Good Box
6.
Open Box
7.
Short Box
8.
Imped Box
9.
Pass /
Fail /Total Box
10.
Apply Button
11.
Reload Button
5. Under
Runs
, enter the number of consecutive diagnostic tests to perform. A value of 0 indicates the test will
run continuously until stopped by the user.
6. Under
Calib.
, enter the estimated Distance To Fault (DTF) value. For information about how to determine the
Section 3.6.11.4, “Determining the Estimated Distance To Fault (DTF)”
.
7. Select
Started
.
IMPORTANT!
A diagnostic test can be stopped by selecting
Stopped
and clicking
Apply
. However, if the test is
stopped in the middle of a diagnostic run, the test will run to completion.
8. Click
Apply
. The state of the Ethernet port will automatically change to
Stopped
when the test is complete.
For information about how to monitor the test and view the results, refer to
Section 3.6.11.1, “Viewing Cable
Section 3.6.11.3
Clearing Cable Diagnostics
To clear the cable diagnostic results, do the following:
1. Navigate to
Ethernet Ports
»
Clear Cable Diagnostics Statistics
. The
Clear Cable Diagnostics Statistics
form appears.