Parameters
12.5 Online Calibration Options (P355 - P358)
BW500 and BW500/L
168
Operating Instructions, 12/2016, A5E33482052-AD
12.4.3
P350 Calibration Security
P350 Calibration Security
zero
Span
‘Reset T’
entry:
0 = no additional
security.
f
Yes
Yes
Yes
1 = in addition to
P000 lock; no
span.
Yes
No
Yes
2 = in addition to
P000; no zero, no
span.
No
No
Yes
3 = in addition to
P000; no zero, no
span, no totalizer
1 (T1) reset.
No
No
No
12.5
Online Calibration Options (P355 - P358)
Note
•
Online calibration options must be enabled (P355 = 1) before they become available.
•
Not available with BW500/L.
12.5.1
P355 Online Calibration Feature
Enables Online Calibration.
Entry:
0 = OFF
f
1 = ON
12.5.2
P356 Online Calibration Reference Weight
Enter the weigh bin reference weight, (in units selected in P005), range 0.000 to 99999 (
f
=
0.000).
Содержание Milltronics BW500
Страница 1: ...Operating Instructions Milltronics BW500 and BW500 L 12 2016 Edition Integrators ...
Страница 12: ...Table of contents BW500 and BW500 L 10 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 14: ...Safety Notes BW500 and BW500 L 12 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 16: ...The Manual BW500 and BW500 L 14 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 48: ......
Страница 68: ...Start Up 6 4 Load Cell Balancing BW500 and BW500 L 66 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 108: ...Operation 8 10 Totalization BW500 and BW500 L 106 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 153: ...Communications 11 7 Error Handling BW500 and BW500 L Operating Instructions 12 2016 A5E33482052 AD 151 ...
Страница 154: ......
Страница 198: ...Troubleshooting 13 2 Specifically BW500 and BW500 L 196 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 208: ...Appendix A 3 Technical support BW500 and BW500 L 206 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 218: ...Index BW500 and BW500 L 216 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 219: ......