Valid ranges of the timebase, if T = Actual value of an already-programmed function
Timebase
max. value
Meaning
Accuracy
ms
99990
Number of ms
+ 10 ms
s
5999
Number of s
+ 1 s
m
5999
Number of min
+ 1 min
The display in programming mode (example):
7ൺ%V
%5
If the referenced block (B6, in the example) returns a value that lies out of the valid range,
the value is rounded up or down to the next valid value.
Parameter preset = Actual value of an already-programmed function
How to include the actual value of an already-programmed function:
1.
Press to move the cursor to the equal sign of parameter T.
Ⴇ
7 K
%5
7 K
%5
WZLFH
3UHVV
2.
Press to change the equal sign into an arrow. If it exists, the last referenced block and
its timebase is shown.
7ൺ%V
%5
3.
Press to move the cursor to the "B" of the shown block, and then press to select the
required block number.
4.
Press to move the cursor to the block's timebase and press to select the required
timebase.
7ൺ%P
%5
Содержание LOGO!
Страница 8: ...Preface LOGO 8 Manual 04 2011 A5E03556174 01 ...
Страница 136: ...Programming LOGO 3 9 Memory space and circuit program size LOGO 136 Manual 04 2011 A5E03556174 01 ...
Страница 278: ...LOGO functions 4 4 Special functions list SF LOGO 278 Manual 04 2011 A5E03556174 01 ...
Страница 302: ...Configuring LOGO 7 2 Setting the default values for LOGO LOGO 302 Manual 04 2011 A5E03556174 01 ...
Страница 366: ...Abbreviations LOGO 366 Manual 04 2011 A5E03556174 01 ...
Страница 372: ...Index LOGO 372 Manual 04 2011 A5E03556174 01 ...
Страница 400: ...Safety instructions 2 3 Notes about usage Basic Panels 28 Operating Instructions 04 2012 A5E02421799 03 ...
Страница 534: ...Index Basic Panels 162 Operating Instructions 04 2012 A5E02421799 03 ...