Gate Clamp Board
MicroHarmony Cell Sizes 40 - 260A Manual
6-2
19001467: Version 1.0
s
6
The gate resistor is connected in series with the cell control board's turn on resistor during turn on, and connected in
series with the cell control board's turn off resistor during turn off. The effective RgON is the sum of the cell control
board RgON and the gate clamp board resistor. Likewise, the effective RgOFF is the sum of the cell control board
RgOFF and the gate clamp board resistor.
The gate emitter capacitor allows independent control of the IGBT's dIc/dt without significantly increasing switching
losses and using a smaller value gate resistor. Cge increases switching losses by nearly 25% but reduces repetitive
turn on current by about 20%, reduces peak repetitive FWD turn off current by about 53%, reduces IGBT turn off
overshoot voltage by about 30%, and reduces IGBT OOS overshoot voltage by about 53%.
Component Values
Component Values
∇
∇
∇
P/N
D1
D2
D3
D4
D5
D6
D7
10000428.00
1.5KE350CA
1.5KE400CA
1.5KE400CA
1.5KE400CA
1.5KE1BCA
1.5KE350CA
1.5KE400CA
10000428.01
Not Installed
Not Installed
Not Installed
Not Installed
Jumper
1.5KE350CA
1.5KE400CA
10000428.02
1.5KE350CA
1.5KE400CA
1.5KE400CA
1.5KE400CA
1.5KE1BCA
Not Installed
Not Installed
10000428.03
1.5KE350CA
1.5KE400CA
1.5KE400CA
1.5KE400CA
1.5KE1BCA
1.5KE350CA
1.5KE400CA
10000428.04
1.5KE350CA
1.5KE400CA
1.5KE400CA
1.5KE400CA
1.5KE1BCA
1.5KE350CA
1.5KE400CA
10000428.05
1.5KE350CA
1.5KE400CA
1.5KE400CA
1.5KE400CA
1.5KE1BCA
1.5KE350CA
1.5KE400CA
P/N
D8
D9
D10
R1, SR1
R2, SR2
C1, SC1
C2, SC2
10000428.00
1.5KE400CA
1.5KE400CA
1.5KE1BCA
Jumper
Jumper
Not Installed
Not Installed
10000428.01
1.5KE400CA
1.5KE400CA
1.5KE1BCA
Jumper
Jumper
Not Installed
Not Installed
10000428.02
Not Installed
Not Installed
Jumper
Jumper
Jumper
Not Installed
Not Installed
10000428.03
1.5KE400CA
1.5KE400CA
1.5KE1BCA
5.1 Ohms
5.1 Ohms
0.022
μ
F
0.022
μ
F
10000428.04
1.5KE400CA
1.5KE400CA
1.5KE1BCA
Jumper
Jumper
0.022
μ
F
0.022
μ
F
10000428.05
1.5KE400CA
1.5KE400CA
1.5KE1BCA
15 Ohms
15 Ohms
Not Installed
Not Installed
Typical Schematic.
Always refer to the latest archived
drawing.
Содержание Eupec
Страница 10: ...Safety Precautions and Warnings MicroHarmony Cell Sizes 40 260A Manual viii 19001467 Version 1 0 s ...
Страница 16: ...Cell Overview MicroHarmony Cell Sizes 40 260A Manual 1 6 19001467 Version 1 0 s 1 ...
Страница 36: ...Installation MicroHarmony Cell Sizes 40 260A Manual 3 4 19001467 Version 1 0 s 3 ...
Страница 42: ...Electrical Description MicroHarmony Cell Sizes 40 260A Manual 4 6 19001467 Version 1 0 s 4 ...
Страница 56: ...Repair Hints MicroHarmony Cell Sizes 40 260A Manual 8 4 19001467 Version 1 0 s 8 ...
Страница 76: ...Drive Calc Express MicroHarmony Cell Sizes 40 260A Manual 10 2 19001467 Version 1 0 s 10 ...
Страница 86: ...Communication Protocol MicroHarmony Cell Sizes 40 260A Manual 11 10 19001467 Version 1 0 s 11 ...
Страница 87: ...MicroHarmony Cell Sizes 40 260A Manual NOTES 19001467 Version 1 0 N 1 s NOTES ...
Страница 88: ...NOTES MicroHarmony Cell Sizes 40 260A Manual N 2 19001467 Version 1 0 s ...
Страница 89: ...MicroHarmony Cell Sizes 40 260A Manual NOTES 19001467 Version 1 0 N 3 s ...
Страница 90: ...NOTES MicroHarmony Cell Sizes 40 260A Manual N 4 19001467 Version 1 0 s ...