Basic Hicom settings for connection to 150 E Office Com 1.0
Basic settings
Nur für den internen Gebrauch
A31003-E1320-S100-4-7620
4-12
Service Manual
ATTENTION: in the event of a modification performed while Caracas Desk is
live, all data and call charge data must first be removed from Caracas Desk (via
the Transfer/Read from Desk/Transfer customer data - yes, with call charge data
menu).
The data and call charge data must be reloaded into Caracas Desk after the
modification in Assistant for Caracas Desk (via the Transfer/Write to Desk/
Transfer customer data - yes, with call charge data menu).
●
Select the Configuration menu item once the data has been successfully loaded.
●
Set the extension types. Extensions 1 - 6 are preconfigured by default as admin-
istration. The preconfigured extensions are to be modified in accordance with re-
quirements. Four items of information are necessary for each extension:
●
Enter the required room number.
●
The Hicom number represents the physical connection PEN in Hicom.
Example: the U
P0/E
extensions (master) on the CBFC (central board) are as-
signed the Hicom numbers as of 1, 2, 3, etc.
These numbers cannot be changed. However, they can be removed as re-
quired by deleting extensions and specified by adding extensions.
●
Enter the required extension number. This number must correspond to your
local network provider’s extension number plan.
●
Type:
–
Guest: Guest extensions
–
Booth1/booth2: telephone booths. As in the case of "guests", individual
calls are itemized. On check-out, the name is not deleted and the status is
immediately set to "free". If a name is not specified at check-in, the original
name is retained. An individual charge factor and minimum charge can be
set for the telephone booth.
–
Service: service extensions such as the reception, kitchen, etc. as for "tele-
phone booth". In the event of check-out or payment, however, trunk access
is not switched.
–
Services without charges: service extensions for which only the charge to-
tal is recorded: no details of the individual calls are recorded.
–
Not used: for special extensions which cannot use Caracas Desk but which
are connected, e.g. entrance telephones, service extensions for which call
detail recording is not carried out via Caracas Desk, etc.
●
If conflicts arise between the extension numbers, the customer data is not trans-
ferred back to Hicom and a message regarding the conflict is output. Please note
that conflicts can also arise with codes 7..., 8..., 9... and 0 (for routes by default,
etc.). These codes can only be checked or changed with Assistant E.
●
Write the data to Caracas Desk (via the Transfer/Write to Desk menu)
Содержание Caracas Desk Rel. 2.0
Страница 1: ...Plus products Service Manual Caracas Desk Rel 2 0 A31003 E1320 S100 4 7620 ...
Страница 7: ...Figures Nur für den internen Gebrauch A31003 E1320 S100 4 7620 0 4 Service Manual ...
Страница 9: ...Tables Nur für den internen Gebrauch A31003 E1320 S100 4 7620 0 6 Service Manual ...
Страница 13: ...System data Caracas Desk Nur für den internen Gebrauch A31003 E1320 S100 4 7620 1 4 Service Manual ...