A31003-E1320-S100-4-7620
Service Manual
3-1
Putting into service with Hicom 100 E, Hicom 150 E 2.2, Hicom 150 E Office Com and Office Po
Nur für den internen Gebrauch
Putting into service
3 Putting into service
3.1 Putting into service with Hicom 100 E, Hicom 150 E 2.2, Hicom 150 E
Office Com and Office Point
Prerequisite
●
The U
P0/E
interface to the system must be connected to the 1st or 2nd Hicom
U
P0/E
port (the port must be authorised for system administration).
●
At least one add-on device must be connected to the reception telephone. Up to
four add-on devices may be connected, the first for hotel features, the second to
fourth mainly for room keys.
●
The printer is to be set to:
2400 bauds, no parity, 1 stop bit and 8 data bits.
●
The Hicom V.24 interface is to be set to 9600 baud.
●
Select 1 for CDRC port under Port assignment in the System settings menu.
●
Central call detail recording (CDRC) in Hicom is to be set to compressed output
format, without recording incoming calls and without call logging.
●
Insert the following as service codes:
*95 for System administration
*91 for Program key
*68 for Send message
#68 for Read/delete (sent) message
●
The first modifiable system information text, which can be sent to in-house users
be entering *68, cannot be modified if Caracas Desk is connected to the Hicom
system. You may only delete the blanks following the text so that the text is trun-
cated to the maximum length of the display text
Notes:
DTMF suffix dialling can be activated for Optiset terminals in the system under Sy-
stem settings/Automatic DTMF in order to avoid having to type in "*53" after a call for
the wake-up service.
Checksum errors 512 and 1024 are displayed the first time the system is put into ser-
vice.
Содержание Caracas Desk Rel. 2.0
Страница 1: ...Plus products Service Manual Caracas Desk Rel 2 0 A31003 E1320 S100 4 7620 ...
Страница 7: ...Figures Nur für den internen Gebrauch A31003 E1320 S100 4 7620 0 4 Service Manual ...
Страница 9: ...Tables Nur für den internen Gebrauch A31003 E1320 S100 4 7620 0 6 Service Manual ...
Страница 13: ...System data Caracas Desk Nur für den internen Gebrauch A31003 E1320 S100 4 7620 1 4 Service Manual ...