BTC-BR User’s Manual
7
2.2 – Functions available for KTCO and MTCO
Measurement of the W Automatic:
it allows measure the tachograph in an automatic way, using as start and
end of measurement a system with optical barrier (optional) and two points of reference 20 meters away from
each other. It is more accurate than the conventional method because it does not require the operator’s
participation at the beginning and end steps of the operation by increasing the accuracy of measurement.
Measurement of the W Manual:
it allows measure the tachograph using two points of reference to a pre-
determinated distance from each other. It is necessary the operator’s intervention for the beginning and end of
the operation. It is the conventional method of measurement.
Roller Set:
it also allows measure the tachograph in an automatic way, using as start and end of measurement
a pulses counting system emitted by the wheel of measurement of distance. It is more accurate than the optical
barrier method because they may have greater distances (50, 100 and 1000 meters) and the loss of pulses in
these cases does not influence as much as the standard distance (20 meters). It also does not require the
operator’s participation at the beginning and end steps of the operation by increasing the accuracy of
measurement.
Reading of Adjusted K:
it reads the value of the constant “K” adjusted in the tachograph. For KTCO you can
adjust it and make a rereading of the new value. For the MTCO the adjustment is made by programming.
Device Testing:
Distance Counter Test:
it allows measure the indication of the odometer and to know whether the
indication of the distance travelled is the actual distance that the vehicle went.
Test Chart:
it allows generate a test chart and to note the conditions of operation of tachographs. It is
executed in 22 steps, has estimated duration of 1h50’ and can be interrupted at any time.
Variable Speed:
it allows programming a constant speed and changing it at any time unless unprogram
the previous speed.
Change Language:
it allows switch the language operation between Portuguese, English and Spanish.
2.3 – Exclusive functions for MTCO
Programming:
Installation:
Read parameters of MTCO:
it allows storing all the parameters described below
Write parameters in MTCO:
it allows recording all the parameters described below
K Adjustment
: programming of the constant of adjustment of the MTCO
N
Adjustment
: programming of the constant of the RPM (optional)
Wheel Circumference
: it records the dynamic radius of the wheel with the tire (only information)
Total Odometer
: it programmes the total value of the distance in kilometers travelled by the vehicle
Vehicle Identification
: it records the vehicle number of chassis where it will be installed the MTCO
Configuration
: Keep the original programming
CAN Configuration
: Keep the original programming
Product Code
: Keep the original programming
Drive Axis:
Keep the original programming
Initial Installation
: it programmes the date on which the MTCO was installed
Calibrate Date:
it programmes the dates of measurement of constant “K”
Seal Number
: Record the name/number of representative that mesure/seal the MTCO
Over Speed
: it programmes the removal of alarm (
D4
) and trigger device noise or light for maximun
speed reached
Date-Time:
MTCO Time:
it allows to correct the date and time that it is programmed in the MTCO
MTCO Time Zone:
it allows programming a value of time zone to be considered on European time.
Keep the original programming.
MTCO Over Time:
It programme dates of automatic exchange of daylight saving.
Disable for national MTCOs. Keep the original programming.
Setup Kitas:
it allows programming the operation of the sensor according to the installed tachograph (only
for MTCO 1390).
Manufacturing
Data:
it shows the date of manufacture of the board of MTCO.
Erase
Memory:
it deletes system errors in the memory of the extended menu. See “Manual of Operation of
MTCO”.
Software Version:
it indicates the software version’s operating in the calibrator. Only for control of lot of the
manufacturer of the equipment.