Parameterization
5.3 Parameter assignment with FB 45/55 and FC 56
ASM 456 interface module
38
Operating Instructions, 07/2015, J31069-D0162-U001-A6-7618
5.3.2
Table of commands for ASM 456
Table of commands of the ASM 456 with standard addressing (FB 45)
The assignment is made in UDT 20/UDT 30 using the "command" variable.
Table 5- 4
ASM 456 commands with normal addressing
Command code
Description
available in
the MOBY system
normal
chained*
01
41
Write to transponder
all
02
42
Read transponder; read fixed code
all
03
43
Initialize transponder
RF300 /
RF620R/RF630R /
MOBY U / D
04
44
Reader status
RF200 / RF300 /
RF620R/RF630R /
MOBY U / D
08
48
Turn off transponder
MOBY U
0A
4A
Switch antenna on/off
RF200 / RF300 /
RF620R/RF630R /
MOBY U / D
0B
4B
Transponder status
RF200 / RF300 /
RF620R/RF630R /
MOBY U
*) Chained commands are not supported by all readers. Please note the relevant information
in the RFID/MOBY system manuals.