Setting up
16
Siemens Building Technologies
Fire Safety & Security Products
02.2010
Protocol frame
1
2 ... n-1
n
command
parameter
end character (CR = 0x0D)
Command:
1 byte ASCII, see: 5.2.5.11 Commands
Response of reader:
1
2 ... n-1
n
command
data
end character (CR = 0x0D)
Data: The response of the reader can be only a short acknowledge like OK or NOK
or any more or less long information you ask for.
Positive acknowledge:
„>“ i.e.: after parameter is changed (Prompt)
Receipt:
Negative acknowledge: Error message as text information
3.2.7
Commands
To read out the actual setting information / parameters only send the command
without any parameter to the selected reader. Each command have to be entered
separately and confirmed by ENTER.
A
Application ID (A A0 A1 A2) 3byte Hex-value
F
File-ID (F File Block Start End)
N
DESFire EV1 key position (N Number)
O
Output length (4/7byte) Serial number (O 0/1)
R
Reset to factory defaults
T
Transponder type – Activation (T 0 1)
V
Version
S
Switch/display Setup
K
Keys (K[A|B] X1 X2 X3 X4 X5 X6)
K
Key (C C1 C2 C3 ……. C14 C15 C16) for DESFire EV1 transponder only
B
ID-Number (B Block Start End), three blocks per sector to calculate!
L
LEDs ( red green yellow buzzer, 1=on/0=off)
D
Impulse/gaP times (D Itime Ptime) or Bit clock for Magstripe (D Bclock)
U
UCI-Configuration
H
Recalculation decimal -> hexadecimal (H number)
Q
Termination and saving of changes
ESC
Termination without saving
All numbers are in Hex, except the Impulse, Gap and Bit clock times.