Setting up
13
Siemens Building Technologies
Fire Safety & Security Products
02.2010
3.2.2
Setting the address CerPass reader protocol (RS485 bus operation, 2-wire)
Bus operation with up to 8 readers connected to controllers CC30xx, DRI or ERI.
All card readers are issued with an individual address as shown in table 3.
DIP 1
DIP 2
DIP 3
DIP 4
Bus address
off off off off
1
off off off
on
2
off off
on
off 3
off off
on on
4
off
on
off off
5
off
on
off
on
6
off
on on
off 7
off
on on on
8
on
off off off
9
on
off off
on
10
on
off
on
off 11
on
off
on on
12
on on
off off
13
on on
off
on
14
on on on
off 15
on on on on
16
Tab. 3
Bus addresses for CerPass reader protocol
3.2.3
Setting the address (Clock/Data)
When the clock/data interface is used there is no need to select a reader address.
as that interface allows only one reader to connect with the interface unit DCU-3 or
with the UCI-interface box.
Selecting the clock data interface see chapter 3.2.4
3.2.4
Communication Interface and protocol selection
The communication interface has to be selected ether to communicate with intelli-
gent controllers via RS485 bus or to connect to a reader interface using Clock/Data
interface.
Within the selected communication interface there are different protocols select-
able.
DIP 5 DIP 6 Communication Interface
Protocol
off off
RS485
bus operation
UCI-reader protocol
off
on RS485
bus operation
CerPass reader protocol
on
off Clock/Data
Interface
Wiegand
on on
Clock/Data Interface
Omron (Magstripe Track II)
Tab. 4
Selection of communication interface