Appendi x F Acoustic Output Reference
F - 14
Instructions for Use
Acoustic Output Reporting Table — Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model:
6C1 HD
Operating mode:
Pulsed Doppler
MI
TIS
TIB
TIC
Index Label
Scan
Non-scan
Non-scan
A
aprt
≤
1
A
aprt
>1
Maximum Value
1.33
-
-
1.36
4.21
4.06
As
soc
iat
ed A
cous
tic
P
ar
am
et
er
s
FDA
IEC
Units
P
r.3
p
ra
(MPa)
1.83
W
o
P
(mW)
-
-
240.29
501.33
min of [W
.3
(z
1
),
I
TA.3
(z
1
)]
Min. of [
P
α
(
z
s
),
I
ta.
α
(
z
s
)]
(mW)
146.65
z
1
z
s
(cm)
4.30
z
bp
z
bp
(cm)
3.28
z
sp
z
b
(cm)
7.30
z@PII
.3max
z
@ max.
I
pi,α
(cm)
4.30
d
eq
(z
sp
)
d
eq
(
z
b
)
(cm)
0.48
f
c
f
awf
(MHz)
1.89
-
-
1.95
1.94
2.50
Dim. of A
aprt
X (cm)
-
-
2.69
2.31
5.36
Y (cm)
-
-
1.40
1.40
1.40
O
ther
Inf
or
m
at
ion
PD
t
d
(
µ
sec)
2.35
PRF
prr
(Hz)
100.16
P
r
@ PII
max
P
r
@ max.
I
pi
(MPa)
2.33
d
eq
@ PII
max
d
eq
@ max.
I
pi
(cm)
0.43
Focal Length
FLx
(cm)
-
-
11.06
29.85
FLy
(cm)
-
-
7.00
7.00
I
pa.3
@ MI
max
I
pa,α
@ max.
MI
(W/cm
2
)
100.81
O
per
at
or
C
ont
rol
Frequency (MHz)
2.00
-
-
2.00
2.00
2.50
Focus (cm)
4.00
-
-
11.06
9.58
29.85
Gate Size (cm)
0.25
-
-
0.25
0.25
0.25
Sample Rate (Hz)
100.16
-
-
7440
9765
11160
a This Index is not relevant to this operating mode.
b This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
# No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
Acoustic Output Reporting Table — Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model:
6C1 HD
Operating mode:
M-Mode
MI
TIS
TIB
TIC
Index Label
Scan
Non-scan
Non-scan
A
aprt
≤
1
A
aprt
>1
Maximum Value
1.40
-
-
0.73
1.55
1.79
As
soc
iat
ed A
cous
tic
P
ar
am
et
er
s
FDA
IEC
Units
P
r.3
p
ra
(MPa)
2.67
W
o
P
(mW)
-
-
148.68
183.69
min of [W
.3
(z
1
),
I
TA.3
(z
1
)]
Min. of [
P
α
(
z
s
),
I
ta.
α
(
z
s
)]
(mW)
76.54
z
1
z
s
(cm)
4.80
z
bp
z
bp
(cm)
3.83
z
sp
z
b
(cm)
4.30
z@PII
.3max
z
@ max.
I
pi,α
(cm)
1.70
d
eq
(z
sp
)
d
eq
(
z
b
)
(cm)
1.19
f
c
f
awf
(MHz)
3.63
-
-
2.00
2.00
3.43
Dim. of A
aprt
X (cm)
-
-
3.67
3.67
3.67
Y (cm)
-
-
1.40
1.40
1.40
O
ther
Inf
or
m
at
ion
PD
t
d
(
µ
sec)
0.46
PRF
prr
(Hz)
600.00
P
r
@ PII
max
P
r
@ max.
I
pi
(MPa)
3.30
d
eq
@ PII
max
d
eq
@ max.
I
pi
(cm)
33.40
Focal Length
FLx
(cm)
-
-
23.00
23.00
FLy
(cm)
-
-
7.00
7.00
I
pa.3
@ MI
max
I
pa,α
@ max.
MI
(W/cm
2
)
318.16
O
per
at
or
C
ont
rol
Frequency (MHz)
2.50
-
-
1.50
1.50
2.50
Focus (cm)
2.00
-
-
23.00
23.00
23.00
Gate Size (cm)
1.00
-
-
1.00
1.00
1.00
Sample Rate (Hz)
600.00
-
-
600
600
600
a This Index is not relevant to this operating mode.
b This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
# No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
Содержание Acuson S2000
Страница 12: ...1 Introduction 1 2 Instructions for Use ...
Страница 14: ...1 Introduction 1 4 Instructions for Use System Review Example of the ultrasound system ...
Страница 84: ...2 Safety and Care 2 54 Instructions for Use ...
Страница 86: ...3 System Setup 3 2 Instructions for Use ...
Страница 112: ...3 System Setup 3 28 Instructions for Use ...
Страница 114: ...4 Examination Fundamentals 4 2 Instructions for Use ...
Страница 144: ...5 Transducer Accessories and Biopsy 5 2 Instructions for Use ...
Страница 196: ...7 Specialty Transducers 7 2 Instructions for Use ...
Страница 200: ...7 Specialty Transducers 7 6 Instructions for Use ...
Страница 202: ...8 Physiologic Function 8 2 Instructions for Use ...
Страница 208: ...9 eSieFusion Imaging 9 2 Instructions for Use ...
Страница 236: ...10 Virtual Touch Applications 10 2 Instructions for Use ...
Страница 258: ...10 Virtual Touch Applications 10 24 Instructions for Use ...
Страница 302: ...Appendix A Technical Description A 44 Instructions for Use ...
Страница 326: ...Appendix B Control Panel and Touch Screen B 24 Instructions for Use ...
Страница 328: ...Appendix C Control Panel C 2 Instructions for Use ...
Страница 394: ...Appendix D On screen Controls D 50 Instructions for Use ...
Страница 444: ...Appendix F Acoustic Output Reference F 2 Instructions for Use ...
Страница 516: ...Appendix F Acoustic Output Reference F 74 Instructions for Use ...
Страница 517: ......
Страница 518: ......