background image

6

13 & 14th relay will be used for control switching only when customer selects 14 relay in config. else for FAN & ALM respectively.

*

Range

Data

Structure

Length

(Register)

Address

Parameter

Hex

Address

1

1

55

1-999

1-9999

55 - 100

Integer

Integer

Integer

1

1

1

40025

40027

40026

0x1A

0x19

0x1B

Step time (Sec.)

Control

Sensitivity(%)

800

-800

Signed
Integer

1

40024

0x18

Target Power
Factor (PF)

Discharge
Time(Sec.)

Integer

Integer

Integer

Integer

Integer

1

1

1

1

1

40029

40031

40028

40030

40032

0x1C

0x1E

0x1D

0x1F

0x20

Over Voltage

Under Voltage

No Voltage

Set

(V)

Over

Voltage

Set Under
Voltage(V)

0 : OFF ; 1 : ON

0 : OFF ; 1 : ON

0 : OFF ; 1 : ON

50 - 277V (L-N); 85 - 480V (L-L)

50 - 240V (L-N); 85 - 415V (L-L)

20

20

0

1

1

0:OFF;1:ON

20 - 100

20 - 80

0 - 100

1 - 10

1 - 5

0-50

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

Integer

1

1

1

1

1

1

1

1

1

1

1

1

1

40033

40035

40037

40039

40041

40043

40034

40036

40038

40040

40042

40044

40045 -
40058

0x21

0x23

0x25

0x27

0x29

0x2B

0x22

0x24

0x26

0x28

0x2A

0x2C

0x2D-
0X3A

THDI Range(%)

Under

Compensation

Set Step Error(%)

Over Temperature

Fan Settings

Hysteresis PF(%)

Relay1-Relay14

THDI

Over

Compensation

Step Error

CT Polarity error

Set Over
Temperature ( C)

0

Hysteresis

oltage

V

(%)

0 : OFF ; 1 : ON

0 : OFF ; 1 : ON

0 : OFF ; 1 : ON

0 : OFF ; 1 : ON

0 : OFF ; 1 : ON

0 : OFF ; 1 : ON

0 : OFF ; 1 : ON

Integer

Integer

1

1

40059

40060

0x3B

0x3C

Trip time setting

Low Current
setting(%)

0 : OFF ; 1 : ON

0

Modbus Register Addresses List

Readable / writable parameters:

Integer

Integer

Integer

Integer

1

1

1

1

0

1

1

1

7200

Set to factory setting range

Reset Total Active Energy

Reset Total Apparent Energy

40011

40012

40013

40014

0x0B

0x0C

0x0D

0x0E

Backlight OFF

(Sec.)

Factory Default

Reset kWh

Reset kVAh

Integer

1

1

Reset Total Reactive Energy

40015

0x0F

Reset kVArh

50

50 - 440

Min value

Max value

Integer

Integer

Integer

1

1

1

0

40016

40017

40018

0x11

0x12

0x10 Password-2

Phase

Compensation ( )

0

Nominal Voltage(V)

9998

0-0, 1-90, 2-120, 3-210, 4-240, 5-330

1

12 / 14*

Integer

Integer

Integer

Integer

1

1

1

1

40021

40023

40020

40022

0x14

0x16

0x15

0x17

Relay Count

Switching Program

Auto Initialization

Control Mode

0 - MANUAL ; 1 - AUTO

0 - Auto ; 1 - Rotation ; 2 - Linear

0 : NO ; 1 : YES

Range

Dat a

Structure

Length

(Register)

Address

Parameter

Hex

Address

Min value:0

Value

Max value : 9998

Integer

1

40000

0x00

Password-1

0

1

2

3

3P4W

3P3W

1P2W

2P2W

Integer

Integer

Integer

Integer

1

1

1

1

40001

0x01

N/W selection

Min value Max value

Integer

Integer

1

2

Integer

1

40004

40005

0x04

0x05

CT primary
(CT Secondary=1)

(A)

PT Secondary (V)

PT primary (V)

Slave id

0x07

40007

Integer

1

40002

0x02 CT Secondary (A)

1

100

100

1 - 9999

500

500000

1

255

1

5

Integer

Integer

1

0x0000

0x0001

1

2

40010

1

0x0000

0x0001

0x0002

None

Odd

Even

40009

0x09

0x0A

Parity

Stop bit

0x0005

0x0006

9600

19200

Meaning

Value

Integer

1

0x0000

300

40008

0x08 Baud rate (bps)

0x0001

600

0x0002

1200

0x0003

2400

0x0004

4800

Formula to find address of individual Harmonic

Note : For Error 0 :No Error ; 1 :Error Present

Meaning

Constant Parameter

Voltage V1N
Voltage V2N
Voltage V3N
Voltage V12
Voltage V23
Voltage V31
Current I1
Current I2
Current I3

0

1

2
3
4
5
6
7
8

Readable parameters: [

: Length (Register) : 2; Data structure : Float,

: Length (Register) : 1; Data structure: Integer]

For Measuring

For Error

Address

Hex

Address

Parameter

30048

0x30

30050

0x32

30046

0x2E

30000

30002

30004

30006

30008

30010

30012

30014

30016

30018

30020

30022

30024

30026

30028

30030

30032

30034

0x00

0x02

0x04

0x06

0x08

0x0A

0x0C

0x0E

0x10

0x12

0x14

0x16

0x18

0x1A

0x1C

0x1E

0x20

0x22

Voltage V1N

Voltage V2N

Voltage V3N

Average Voltage LN

Voltage V12

Voltage V23

Voltage V31

Average Voltage LL

Current I1

Current I2

Current I3

Average Current

kW1

kW2

kW3

kVA1

kVA2

kVA3

30038

0x26

30040

0x28

30042

0x2A

30044

0x2C

30052

0x34

30054

0x36

30056

0x38

30058

30060

0x3A

0x3C

30062

30064

30066

0x3E

0x40

0x42

30124

0x7C

30126

30128

30130

30132

30134

30136

0x7E

0x80

0x82

0x84

0x86

0x88

THD of Voltage V3N

THD of Voltage V1N

THD of Voltage V2N

THD of Voltage V12

THD of Voltage V23

THD of Voltage V31

THD of Current I1

30138

30140

30684

0x8A

0x8C

0x2AC

THD of Current I2

THD of Current I3

Serial number in HEX

Total Harmonic Distortion(THD)

30071

30072

30073

0x47

0x48

0x49

30067

0x43

30068

0x44

PF1

PF2

Total kVAr

30036

0x24 kVAr1

kVAr2

kVAr3

Total kW

Total kVA

PF3

Average PF

Frequency

kWh

kVAh

kVArh

Temperature

No Voltage Error

Under Voltage Error

Over Voltage Error

Over compensate Error

Under compensate Error

CT Error

{142 + [(Harmonic no-2) x 2] + 60 x
Constant Parameter }
For Example,
To find the 14 Harmonic address of
Voltage V31 following formula can be used:
Formula with the parameter :
{142 + [(Harmonic no-2) x 2] + 60 x C P}
Eg. {142 + [(14-2) x 2 ] + 60 x 5} = 466
So, Check the 14 Harmonic of Voltage V31
at 466 address.

th

th

Address

Hex

Address

Parameter

Address

Hex

Address

Parameter

Integer

1

40003

0x03

CT primary
(CT Secondary=5)

(A)

5

5 - 9999

0

0 - 100

Integer

1

40019

0x13

Threshold

(%)

Voltage

30069

0x45

THD I Error

30070

0x46

Temperature Error

30074
-30087

0x4A-
0x57

30088

30090-
30116

0x58

0x5A -

0x74

Digital Input Status

Relay1-Relay12/14* Status

Bank1 - Bank 12/14* Value

Note: For Status 0:OFF;1:ON

00000-
00013

00000-

00013

0x00-

0x0D

0x00-
0x0D

Relay1 - Relay 12/14*

Relay1 - Relay 12/14*

Address

Address

Hex

Address

Hex

Address

Parameter

Parameter

Read Coil Status

Force Single Coil:

Meaning

8/12/14*

8/12/14*

8/12/14*

Содержание 7UG0571-1FT20

Страница 1: ...e 50 to 440 VAC L L 30 to 250 VAC L N AC Network 3Φ 4W 3Φ 3W 2Φ 2W 1Φ 2W Display parameters Power Factor True RMS voltage Current Frequency Power KW KVA KVAr Energy KWh KVAh Temperature Control Supply 90 to 250 VAC 50 60Hz Power consumption 15VA Frequency range 50 60Hz Operating temperature 0 C to 60 C Humidity upto 95 without moisture condensation Alarm mode relay output Over voltage Under voltag...

Страница 2: ...col Communication address Transmission Mode Data types Transmission distance Transmission speed Parity Stop bits RS AND 485 MODBUS RTU 1 to 255 Half duplex Float and Integer 500 Meter maximum 300 600 1200 2400 4800 9600 19200 in bps None Odd Even 1 or 2 7UG057 L N V I R C NO RS485 T1 T2 0 5 Nm 0 4 Nm 5 Solid 1 x 0 75 to 2 5 mm2 2 x 0 5 to 2 x 1 5 mm2 0 5 mm2 5 Stranded with end sleeve 1 x 0 5 to 2...

Страница 3: ...phase Displays current of 1st phase Displays THD of current of 1st phase Press key 1st time Displays active power of 1st phase Displays reactive power of 1st phase Displays apparent power of 1st phase Press key 3rd time Press key 2nd time Displays active energy of 1st phase Displays reactive energy of 1st phase Displays apparent energy of 1st phase Displays temperature OK OK OK Parameter Key Key P...

Страница 4: ...Trip Time No Yes Under Voltage Set No Yes Harmonics Range No Yes No Yes Over Voltage Set Step Error Step Error Setting CT Polarity Error Over Temperature Hysteresis Voltage Hysteresis PF Factory Default Yes No Temperature Range Setting Fan Setting Reset kVAh Reset Energy Password Correct Reset kWh No Yes Yes No Reset kVArh Bank 1 Bank 2 Bank 5 Bank 6 Bank 7 Bank 3 Bank 13 Bank 14 Bank 4 Bank 8 Ban...

Страница 5: ... customer wants to reset energy 5min 5min Inst 5min 5min NA Inst 5min 2 5min 1min Inst 1min 1min NA Inst 50 240V L N 85 415 L L ON OFF 50 277V L N 85 480 L L ON OFF ON OFF ON OFF ON OFF 20 to 80 ON OFF 0 100 ON OFF ON OFF 1 to 10 1 to 5 20 100 50 YES NO YES NO YES NO YES NO YES NO 0001 9999 ON OFF Name of Parameter No Voltage Release Trip time setting TRIP TIME Over Voltage Nomenclature Default Va...

Страница 6: ...02 CT Secondary A 1 100 100 1 9999 500 500000 1 255 1 5 Integer Integer 1 0x0000 0x0001 1 2 40010 1 0x0000 0x0001 0x0002 None Odd Even 40009 0x09 0x0A Parity Stop bit 0x0005 0x0006 9600 19200 Meaning Value Integer 1 0x0000 300 40008 0x08 Baud rate bps 0x0001 600 0x0002 1200 0x0003 2400 0x0004 4800 Formula to find address of individual Harmonic Note For Error 0 No Error 1 Error Present Meaning Cons...

Страница 7: ...irst out sequence This option will automatically switch in and out the capacitors according to the targeted power factor sensitivity setting and the re connection time setting This automatic switching program uses intelligent switching sequence The step switching sequence is not fixed and the program automatically selects the most appropriate steps to switch in or out in order to achieve shortest ...

Отзывы: