background image

ETH8020 - 20 Relays at 16A, 8 Analogue Inputs

Technical Documentation

Overview

The ETH8020 provides 20 volt free contact relay outputs with a current rating of up to 16Amp each and 8 analogue 
inputs. The module is powered from a 12vdc supply which can be regulated or unregulated. The DC input jack is 
2.1mm with positive core polarity, DC supplies are required to supply at least 1A at 12vdc. The relays are SPCO 
(Single Pole Change Over) types. The normally open, normally closed and common pins are all available on the screw 
terminals.The Relays on the ETH8020 can be controlled from the inputs on the ETH484 or another ETH8020. This 
offers the opportunity to construct a system where an input can control an output anywhere on the earth provided both 
locations are connected to the network/internet.

Operating temperature

-40C to +70C

LED indication

The ETH8020 provides a red LED mounted immediately next to each relay to indicate whether it is in a powered state 
(LED on), there is also two LED's mounted in the Ethernet connector which will flash with Ethernet traffic. Finally 
there is a green power LED next to the processor.

Relay power rating

If the contact load voltage and current of the relay are in the region enclosed by the solid and dotted lines in the figure 
below, the relay can perform stable switching operation. If the relay is used at a voltage or current exceeding this 
region, the life of the contacts may be significantly shortened.

load
type

Typical applications

Rating

Max DC load capacity

 

AC1

Non inductive or

slightly inductive loads

16A @ 250V AC

AC15

Control of

electromagnetic load

(>72VA)

3A @ 120V AC

1.5A @ 240V AC

AC3

Control of motor

750W

DC1

Non inductive or

slightly inductive loads

16A @ 24V DC

DC13

Control of

electromagnetic

loads

0.22A @ 120V DC

0.1A @ 250V DC

A full datasheet for the relays used on the ETH8020 is here: 

HF115FD datasheet

© Devantech Ltd  02/07/19

ETH8020 Documentation  

     1/17

Содержание ETH008

Страница 1: ...8020 provides a red LED mounted immediately next to each relay to indicate whether it is in a powered state LED on there is also two LED s mounted in the Ethernet connector which will flash with Ethernet traffic Finally there is a green power LED next to the processor Relay power rating If the contact load voltage and current of the relay are in the region enclosed by the solid and dotted lines in...

Страница 2: ...Free Contacts NC normally connected C common NO normally open Power relays Four 16A volt free contact relays are provided for switching a common input between a normally closed output and a normally open output The relay coil is powered by the 12vdc incoming supply on user command Coil C Relay in passive state NC NO Coil C Relay in powered state NC NO Devantech Ltd 02 07 19 ETH8020 Documentation 2...

Страница 3: ...bit conversion will be in the lower 10 bits of the 16 bit integer with the upper 6 bits being 0 There is a 5v supply available on the 3 pin terminal block between the analogue inputs Examples Example input connecting a potentiometer Connecting a potentiometer should be the simplest of tasks either end of the pot should be wired to the 5v and 0v respectively the output pin of the pot is then wired ...

Страница 4: ... there or any other used IP addresses on the network The subnet mask dictates what IP addresses the PC can communicate with we set this to 255 255 255 0 so the PC can talk to any module with an IP address of 192 168 0 x The default gateway is likely to be the IP address that the internet connection is located at and the DNS server can be either your router address or Google provide a DNS service a...

Страница 5: ... bar please note this only works in windows You will be prompted for a password as shown below The default login is Username admin Password password The ability to change these settings is shown in the configuration section You should now see the following web page This web page will allow you to switch the relays on and off by clicking the relay buttons the red gray circles It also contains a lin...

Страница 6: ...lso offers the option to set a password that will be required to change any of the relay states or digital outputs using TCP IP commands this is explained in the TCP IP password section All settings are saved to memory so be careful to remember the username and password Default password settings are shown in the picture below Version 2 now offers a latched outputs option this will automatically sa...

Страница 7: ... accepts an IP address or hostname which will be converted to an IP address by the DNS server supplied in the board configuration above If the module is on the local network then you can use the assigned IP address if the target is over the internet then you need to supply the gateway in the configuration internet source IP like your router and the Address of target board is the IP address of the ...

Страница 8: ...inputs to a PC it operates on the default port of 17494 the default password of password although both are easily changed in the source code and requires the ETH8020 input mapping to be pointed at the host PC IP address As it s having to constantly listen it s a multi thread program The input monitor program is available as Visual C express ready built installation files here or as project with so...

Страница 9: ...ond with 2 bytes to form an 16 bit integer high byte first 58 0x3A ASCII text commands allows a text string to switch outputs see section below 119 0x77 Get Serial Number Returns the unique 6 byte MAC address of the module 120 0x78 Get Volts returns relay supply voltage as byte 125 being 12 5V DC 121 0x79 Password Entry see TCP IP password board will return 1 for success or 2 for failure 122 0x7A ...

Страница 10: ...ade 1 30 seconds until TCP IP password protection is re enabled All authorised commands set the timer back to 30 seconds including this one 255 TCP IP password is not enabled ASCII text commands DOA and DOI V5 firmware needed Following customer request we have added a feature that allows the outputs to be switched using an ASCII string devices like a Mobotix camera can now switch relays with simpl...

Страница 11: ...DG834 router After logging on to your routers setup page the first thing to do is create a new service Click on the Services menu then Add Custom Service Enter a name for the service select TCP and enter the ETH8020 s port address for both the start and finish ports Click Apply Now go to the Firewall Rules menu and click Add in the Inbound services section Select the ETH8020 service and ALLOW alwa...

Страница 12: ...on Visual studio express is provided free from Microsoft http www microsoft com exPress download The test program is able to control an ETH8020 on the local network or over the internet using your router port forwarding an example of the setup procedure is described on the page above To point the example program at your router go to menu Setup Set Comport and click Custom IP then enter the Router ...

Страница 13: ...y now on all http pages http set output commands added V5 08 13 14 Fixed ASCII command buffer overruns V6 02 25 15 Corrected issue with http password length of 12 characters V7 11 16 15 Digital input mapping functionality added html commands now respond with board relay and input status V8 29 11 16 HTML page now has relays numbered for easy identification V9 03 04 17 Mapped inputs socket closure c...

Страница 14: ...ord the program will require it to be entered by clicking the password button Following a successful connection you will now be able to click the update button to select a file Devantech Ltd 02 07 19 ETH8020 Documentation 14 17 ...

Страница 15: ... Devantech Ltd 02 07 19 ETH8020 Documentation 15 17 ...

Страница 16: ... necessary to reset the ETH8020 to its shipped condition then the end two contacts of the row of 5 holes near the large chip on the side nearest the Ethernet connection must be shorted together at board power up Keep the pins shorted until the green power LED starts to flash this will take up to 5 seconds The green LED will flash as the settings are reset please wait until the LED finishes flashin...

Страница 17: ...Board dimensions Devantech Ltd 02 07 19 ETH8020 Documentation 17 17 ...

Отзывы: