Siemens PM240-2_EN_rev00-30082019.docx
12-1
12 ACTIVE FAULTS & ALERT
SIEMENS inverters emit warnings type A (ALERT) or F (FAULT).
Errors are identified by the letter of the type (A/F), followed by a digit code that allows you to trace the
causes that have generated and their possible solutions.
The errors are displayed: on the BOP operator panel.
A description of the error, the possible causes and solutions, is available in the following chapter.
The list of all possible errors and their solutions can be found in the standard manual SIEMENS V20, to
which you could refer.
To
reset an error
, select the error and follow the following procedure through the BOP (see below).
In general, facing to a non-compliance detected, the inverter behaves as follows:
Errors Type A (Alarm) are minor errors that, in principle, have no influence on the behavior of the
inverter / LIFT.
The error A remains active, until is existing the cause that has determined it, then it reset.
Errors TYPE F (Fault) are serious flaws that lead to the immediate arrest of the inverter and the lift
that is placed safely via simultaneous closing of the valve.
The error F remains active even after the disappearance of the cause that determines it and has to be
resetted manually.
Note:
If there are multiple active faults and alarms, the BOP first displays all faults one after another. Once
all faults are displayed, it displays all alarms in succession and the display continues to repeat.
12.1 RESET OF THE ANOMALIES
Acknowledging / clearing faults (FAULT)
To navigate through the current list of faults, press
▲ or ▼ on the BOP panel.
To clear / acknowledge the fault, press FN.
After you acknowledge or ignore the fault, the screen returns to the previous display. The fault icon remains
active until the fault is cleared / acknowledged.
Note:
the anomalies screen displays again if the fault has not been cleared and if any button is not pressed
12.2 ANOMALIES CODES LIST
WARNING: To understand the causes, after having acquired the error code it may be necessary
to read the error index in the parameter r0949
Anomaly
Cause
Solution
F01042
Parameter error during project
download
An error was detected when
downloading (upload or update) a
project using the commissioning
software (e.g. incorrect parameter
value)
Enter the correct value in the
specified parameter
Identify the parameter that
restricts the limits of the specified
parameter (when it dependent by
another parameter)
F01043
Fatal error at project download
A fatal error was detected when
downloading (upload or update) a
project using the commissioning
software
Carefully note any other
messages/signals and remove
their cause.
Boot from previously saved files
(power off/ power on)
Contact OMARLIFT Support
F01072
Memory card restored from the
backup copy
The Control Unit was switched-off
while writing to the memory card.
This is why the visible partition
became defective
After switching on, the data from
the non-visible partition (backup
copy) were written to the visible
partition
Check that the firmware and
parameterization is up-to-date
Contact OMARLIFT Support if the
problem persist
Содержание 6SL3210-1PE21-1AL0
Страница 1: ...Siemens PM240 2_EN_rev00 30082019 docx 0 1 0 INVERTER SIEMENS S120 PM240 2 for HI POWER UNITS ...
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 12: ...3 4 Siemens PM240 2_EN_rev00 30082019 docx Figure 3 PM240 2 frame size FSD FSE ...
Страница 22: ......
Страница 24: ......
Страница 28: ......
Страница 34: ......
Страница 39: ...Siemens PM240 2_EN_rev00 30082019 docx 7 5 ...
Страница 40: ......
Страница 48: ......
Страница 50: ......