Siemens PM240-2_EN_rev00-30082019.docx
6-3
6.4
MEANING OF THE LEDS
Function of the LEDs
There are four LEDs on the front panel of the CU310-2 PN's housing (see CU310-2 PN Interface Overview,
Figure 13).
Table 11 LEDs
RDY
Ready
COM
Status of the fieldbus communication
OUT>5V
Encoder current supply > 5 V (TTL/HTL)
MOD
Operating mode (reserved)
The various LEDs are switched on and off as the control unit is powered up (depending on the phase the
system is currently in). When switched on, the color of the LEDs shows the status of the corresponding
power-up phase (see Behavior of the LEDs during booting).
In the event of a fault, power up will be ended in the corresponding phase. The LEDs that are switched on,
retain their color at this particular instant in time, so that the fault can be determined based on the
combination of LEDs that are switched on (bright) and switched off (dark).
All the LEDs go out briefly if the CU310-2 PN has powered up without error. The system is ready for
operation when the LED "RDY" is permanently green.
All the LEDs are controlled by the software loaded during operation (see Behavior of the LEDs in the
operating state).
Behavior of the LEDs during booting
For information about the start-up phase with verification software / firmware, refer to the manual SIEMENS
S120 - GH6
Behavior of the LEDs in the operating state
Table 12 Description of the LEDs during operation of the CU310-2 PN
LED
Color
Stat
Description / cause
Remedy
RDY
(READY)
-
OFF
The electronics power supply is missing or
outside the permissible tolerance range.
Check the power
supply
Green
Continuous light
The unit is ready for operation.
Cyclic DRIVE-CLiQ communication is in
progress.
-
Flashing light
1x2 sec
Commissioning/reset
-
Flashing
light
2x1 sec.
Writing to the memory card.
-
Red
Flashing
light
2x1 sec.
General fault
Check parameter
assignment/
configuration
Red/ Green
Flashing
light
1x2 sec
The control unit is ready for operation, but
there are no software licenses.
Install the missing
licenses.
Orange
Flashing
light
1x2 sec
Updating the firmware of the DRIVE-CLiQ
components.
-
Flashing
light
2x1 sec.
DRIVE-CLiQ component firmware update
completed. Waiting for POWER ON of the
corresponding components.
Switch on the
component.
Green/
Orange
or
Red/ Orange
Flashing
light
2x1 sec.
Recognition of the component via LED is
activated (see SINAMICS S120/S150 List
Manual.)
Note
: Both options depend on the LED
status when component recognition is
activated.
-
Содержание 6SL3210-1PE21-1AL0
Страница 1: ...Siemens PM240 2_EN_rev00 30082019 docx 0 1 0 INVERTER SIEMENS S120 PM240 2 for HI POWER UNITS ...
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 12: ...3 4 Siemens PM240 2_EN_rev00 30082019 docx Figure 3 PM240 2 frame size FSD FSE ...
Страница 22: ......
Страница 24: ......
Страница 28: ......
Страница 34: ......
Страница 39: ...Siemens PM240 2_EN_rev00 30082019 docx 7 5 ...
Страница 40: ......
Страница 48: ......
Страница 50: ......